Precise diagnosis in intrathoracic malignancies is paramount for adequate treatment planning. Standard approach is histologic analysis from targeted biopsy obtained with different invasive procedures. Rarely, in difficult clinical scenarios, even gold standard diagnostic procedures can be ineffective in obtaining a satisfying result. Procedural developments and technological improvements applied to the chosen technique can be helpful to deal with such situation. We present two clinical cases of suspected intrathoracic malignancy in which repeated unsuccessful diagnostic procedures had already been attempted. We adopted a protocol based on intraoperative fluorescence during diagnostic thoracoscopy to increase diagnostic efficacy. In both cases we obtained a precise pathological diagnosis.

Intraoperative near-infrared molecular imaging for diagnostic thoracoscopy in difficult clinical scenario

Guerrera, Francesco;Femia, Federico;Lyberis, Paraskevas;Filosso, Pier Luigi;Lausi, Paolo Olivo;Ruffini, Enrico
2022-01-01

Abstract

Precise diagnosis in intrathoracic malignancies is paramount for adequate treatment planning. Standard approach is histologic analysis from targeted biopsy obtained with different invasive procedures. Rarely, in difficult clinical scenarios, even gold standard diagnostic procedures can be ineffective in obtaining a satisfying result. Procedural developments and technological improvements applied to the chosen technique can be helpful to deal with such situation. We present two clinical cases of suspected intrathoracic malignancy in which repeated unsuccessful diagnostic procedures had already been attempted. We adopted a protocol based on intraoperative fluorescence during diagnostic thoracoscopy to increase diagnostic efficacy. In both cases we obtained a precise pathological diagnosis.
2022
27
1
176
179
diagnostics; diffuse large B-cell lymphoma; malignant pleural mesothelioma
Guerrera, Francesco; Femia, Federico; Lyberis, Paraskevas; Filosso, Pier Luigi; Lausi, Paolo Olivo; Ruffini, Enrico
File in questo prodotto:
File Dimensione Formato  
rpor-27-1-176.pdf

Accesso aperto

Tipo di file: PDF EDITORIALE
Dimensione 905.64 kB
Formato Adobe PDF
905.64 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1882262
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact