Aluminium is the most common substrate in studies using impactors for the measurement of the number or the weight of size-segregated atmospheric particulate matter (PM), as its characteristics perfectly fit impactor requirements. However, its use is not recommended by manufacturers when one of the purposes of the study is the determination of the metal content in the sample. The aim of this work was to develop an efficient analytical procedure for the removal and acid digestion of PM samples collected on aluminium foils by a cascade impactor to perform the determination of metals. The possibility of performing the trace metal analysis of PM samples collected using aluminium foils is of great importance, as it allows the determination of an accurate size distribution and the elemental composition of the PM collected on each impactor stage. Two procedures were optimised by using different digestion and analysis techniques. Both procedures were then applied to the two halves of several Dekati low-pressure impactor (DLPI) samples, and the results were critically compared. The two procedures proved to be effective in the determination of extremely low concentrations of a large suite of analytes in different size fractions of PM emitted by a brake system.

Methods for Elemental Analysis of Size-Resolved PM Samples Collected on Aluminium Foils: Results of an Intercomparison Exercise

Conca Eleonora;Malandrino Mery
;
Diana Aleandro;Abollino Ornella;Giacomino Agnese;
2022-01-01

Abstract

Aluminium is the most common substrate in studies using impactors for the measurement of the number or the weight of size-segregated atmospheric particulate matter (PM), as its characteristics perfectly fit impactor requirements. However, its use is not recommended by manufacturers when one of the purposes of the study is the determination of the metal content in the sample. The aim of this work was to develop an efficient analytical procedure for the removal and acid digestion of PM samples collected on aluminium foils by a cascade impactor to perform the determination of metals. The possibility of performing the trace metal analysis of PM samples collected using aluminium foils is of great importance, as it allows the determination of an accurate size distribution and the elemental composition of the PM collected on each impactor stage. Two procedures were optimised by using different digestion and analysis techniques. Both procedures were then applied to the two halves of several Dekati low-pressure impactor (DLPI) samples, and the results were critically compared. The two procedures proved to be effective in the determination of extremely low concentrations of a large suite of analytes in different size fractions of PM emitted by a brake system.
2022
27
21
7442
7442
https://www.mdpi.com/1420-3049/27/21/7442
impactor, aluminium foils, digestion, elemental analysis, metals, atmospheric particulate matter
Conca Eleonora, Malandrino Mery, Diana Aleandro, Abollino Ornella, Giacomino Agnese, Bartrolí Rafael, Moreno Teresa, Querol Xavier, Amato, Fulvio
File in questo prodotto:
File Dimensione Formato  
Molec_2022_Methods for Elemental Analysis of SizeResolved PM_Conca et al.pdf

Accesso aperto

Descrizione: Molec_2022_Methods for Elemental Analysis of SizeResolved PM_Conca et al
Tipo di file: PDF EDITORIALE
Dimensione 1.92 MB
Formato Adobe PDF
1.92 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1884261
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact