: The aim of this retrospective multicenter observational study is to test the feasibility and safety of a combined extracorporeal CO 2 removal (ECCO 2 R) plus renal replacement therapy (RRT) system to use an ultraprotective ventilator setting while maintaining (1) an effective support of renal function and (2) values of pH within the physiologic limits in a cohort of coronavirus infectious disease 2019 (COVID-19) patients. Among COVID-19 patients admitted to the intensive care unit of 9 participating hospitals, 27 patients with acute respiratory distress syndrome (ARDS) and acute kidney injury (AKI) requiring invasive mechanical ventilation undergoing ECCO 2 R-plus-RRT treatment were included in the analysis. The treatment allowed to reduce V T from 6.0 ± 0.6 mL/kg at baseline to 4.8 ± 0.8, 4.6 ± 1.0, and 4.3 ± 0.3 mL/kg, driving pressure (ΔP) from 19.8 ± 2.5 cm H 2 O to 14.8 ± 3.6, 14.38 ± 4.1 and 10.2 ± 1.6 cm H 2 O after 24 hours, 48 hours, and at discontinuation of ECCO 2 R-plus-RRT (T3), respectively ( p < 0.001). PaCO 2 and pH remained stable. Plasma creatinine decreased over the study period from 3.30 ± 1.27 to 1.90 ± 1.30 and 1.27 ± 0.90 mg/dL after 24 and 48 hours of treatment, respectively ( p < 0.01). No patient-related events associated with the extracorporeal system were reported. These data show that in patients with COVID-19-induced ARDS and AKI, ECCO 2 R-plus-RRT is effective in allowing ultraprotective ventilator settings while maintaining an effective support of renal function and values of pH within physiologic limits.
Extracorporeal CO 2 Removal During Renal Replacement Therapy to Allow Lung-Protective Ventilation in Patients With COVID-19-Associated Acute Respiratory Distress Syndrome
Fanelli, Vito;Ricci, Davide;Terragni, Pierpaolo;Ranieri, V Marco
2023-01-01
Abstract
: The aim of this retrospective multicenter observational study is to test the feasibility and safety of a combined extracorporeal CO 2 removal (ECCO 2 R) plus renal replacement therapy (RRT) system to use an ultraprotective ventilator setting while maintaining (1) an effective support of renal function and (2) values of pH within the physiologic limits in a cohort of coronavirus infectious disease 2019 (COVID-19) patients. Among COVID-19 patients admitted to the intensive care unit of 9 participating hospitals, 27 patients with acute respiratory distress syndrome (ARDS) and acute kidney injury (AKI) requiring invasive mechanical ventilation undergoing ECCO 2 R-plus-RRT treatment were included in the analysis. The treatment allowed to reduce V T from 6.0 ± 0.6 mL/kg at baseline to 4.8 ± 0.8, 4.6 ± 1.0, and 4.3 ± 0.3 mL/kg, driving pressure (ΔP) from 19.8 ± 2.5 cm H 2 O to 14.8 ± 3.6, 14.38 ± 4.1 and 10.2 ± 1.6 cm H 2 O after 24 hours, 48 hours, and at discontinuation of ECCO 2 R-plus-RRT (T3), respectively ( p < 0.001). PaCO 2 and pH remained stable. Plasma creatinine decreased over the study period from 3.30 ± 1.27 to 1.90 ± 1.30 and 1.27 ± 0.90 mg/dL after 24 and 48 hours of treatment, respectively ( p < 0.01). No patient-related events associated with the extracorporeal system were reported. These data show that in patients with COVID-19-induced ARDS and AKI, ECCO 2 R-plus-RRT is effective in allowing ultraprotective ventilator settings while maintaining an effective support of renal function and values of pH within physiologic limits.File | Dimensione | Formato | |
---|---|---|---|
Extracorporeal_CO2_Removal_During_Renal.9.pdf
Accesso aperto
Tipo di file:
PDF EDITORIALE
Dimensione
684.67 kB
Formato
Adobe PDF
|
684.67 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.