Abstract OBJECTIVES: EUROMACS is a registry of the European Association for Cardio-Thoracic Surgery (EACTS) whose purpose is to gather clinical data related to durable mechanical circulatory support for scientific purposes and to publish annual reports. Because the treatment of children with end-stage heart failure has several significantly different characteristics than the treatment of adults, data and outcomes of interventions are analysed in this dedicated paediatric report. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 31 December 2017 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events. RESULTS: Twenty-five hospitals contributed 237 registered implants in 210 patients (81 ♀, 129 ♂) to the registry. The most frequent diagnosis was any form of cardiomyopathy (71.4%) followed by congenital heart disease (18.6%). Overall mean support time on a device was 11.6 months (±16.5 standard deviation). A total of 173 children (82.4%) survived to transplant, recovery or are ongoing; 37 patients (17.6%) died while on support within the observed follow-up time. At 12 months 38% of patients received transplants, 7% were weaned from their device and 15% died. At 24 months, 51% of patients received transplants, 17% died while on support, 22% were on a device and 9% were explanted due to myocardial recovery. The adverse events rate per 100 patient-months was 0.2 for device malfunction, 0.05 for major bleeding, 0.06 for major infection and 0.03 for neurological events within the first 3 months after implantation. CONCLUSIONS: The first paediatric EUROMACS report reveals a low transplant rate in European countries within the first 2 years of implantation compared to US data. The 1-year survival rate seems to be satisfactory. Device malfunction including pump chamber changes due to thrombosis was the most frequent adverse event.

The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): first EUROMACS Paediatric (Paedi-EUROMACS) report

Loforte A;
2018-01-01

Abstract

Abstract OBJECTIVES: EUROMACS is a registry of the European Association for Cardio-Thoracic Surgery (EACTS) whose purpose is to gather clinical data related to durable mechanical circulatory support for scientific purposes and to publish annual reports. Because the treatment of children with end-stage heart failure has several significantly different characteristics than the treatment of adults, data and outcomes of interventions are analysed in this dedicated paediatric report. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 31 December 2017 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events. RESULTS: Twenty-five hospitals contributed 237 registered implants in 210 patients (81 ♀, 129 ♂) to the registry. The most frequent diagnosis was any form of cardiomyopathy (71.4%) followed by congenital heart disease (18.6%). Overall mean support time on a device was 11.6 months (±16.5 standard deviation). A total of 173 children (82.4%) survived to transplant, recovery or are ongoing; 37 patients (17.6%) died while on support within the observed follow-up time. At 12 months 38% of patients received transplants, 7% were weaned from their device and 15% died. At 24 months, 51% of patients received transplants, 17% died while on support, 22% were on a device and 9% were explanted due to myocardial recovery. The adverse events rate per 100 patient-months was 0.2 for device malfunction, 0.05 for major bleeding, 0.06 for major infection and 0.03 for neurological events within the first 3 months after implantation. CONCLUSIONS: The first paediatric EUROMACS report reveals a low transplant rate in European countries within the first 2 years of implantation compared to US data. The 1-year survival rate seems to be satisfactory. Device malfunction including pump chamber changes due to thrombosis was the most frequent adverse event.
2018
54
5
800
808
https://pubmed.ncbi.nlm.nih.gov/32364221/
de By TMMH; Schweiger M; Waheed H; Berger F; Hübler M; Özbaran M; Maruszewski B; Napoleone CP; Loforte A; Meyns B; Miera O; Contributing clinicians...espandi
File in questo prodotto:
File Dimensione Formato  
Ped Report II EUROMACS.pdf

Accesso riservato

Descrizione: Ped Report II EUROMACS
Tipo di file: PDF EDITORIALE
Dimensione 1.7 MB
Formato Adobe PDF
1.7 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1897953
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 27
social impact