Objectives: Myocardial recovery allows for left ventricular assist device (LVAD) explantations after long-term support. Several surgical approaches, including interventional decommissioning, off-pump explantation using a custom-made plug and complete LVAD removal through redo sternotomy, have been described. We present the results from an evaluation of the long-term follow-up of patients who received a titanium sintered plug after LVAD explantation. Methods: We performed a retrospective, European, multicentre analysis of patients who received a titanium sintered plug to seal the apical fixation ring after LVAD explantation. Data were collected from a questionnaire that included demographics, procedural details and follow-up information. Results: Out of 54 contacted centres in 12 countries (n = 179 patients), a total of 68 patients were successfully included in the study. The median follow-up was 34 months (interquartile range: 17-58.5 months); 57 (84%) patients had >1-year follow-up. At the time of the last follow-up, 55 (81%) patients were alive, with a Kaplan-Meier 1-year survival of 90.1% (95% confidence interval: 84.0-98.1%) and a 5-year survival of 80.0% (95% confidence interval: 68.4-92.9%). One patient (1.5%) developed a plug infection originating from an infected part of the incorporated driveline and, after complete removal, is currently in good condition. No postoperative stroke has been reported after plug implantation. Conclusions: In this European multicentre study, the use of a custom-made titanium plug to close the apical fixation ring after LVAD explantation resulted in a low incidence of plug-related complications. With the volume of patients undergoing LVAD explantations after myocardial recovery increasing, the plug has evolved as a simple alternative to more invasive device explantation procedures or decommissioning with a high risk for infection of the remaining system or stroke.

Results from a multicentre evaluation of plug use for left ventricular assist device explantation.

Loforte A;
2022-01-01

Abstract

Objectives: Myocardial recovery allows for left ventricular assist device (LVAD) explantations after long-term support. Several surgical approaches, including interventional decommissioning, off-pump explantation using a custom-made plug and complete LVAD removal through redo sternotomy, have been described. We present the results from an evaluation of the long-term follow-up of patients who received a titanium sintered plug after LVAD explantation. Methods: We performed a retrospective, European, multicentre analysis of patients who received a titanium sintered plug to seal the apical fixation ring after LVAD explantation. Data were collected from a questionnaire that included demographics, procedural details and follow-up information. Results: Out of 54 contacted centres in 12 countries (n = 179 patients), a total of 68 patients were successfully included in the study. The median follow-up was 34 months (interquartile range: 17-58.5 months); 57 (84%) patients had >1-year follow-up. At the time of the last follow-up, 55 (81%) patients were alive, with a Kaplan-Meier 1-year survival of 90.1% (95% confidence interval: 84.0-98.1%) and a 5-year survival of 80.0% (95% confidence interval: 68.4-92.9%). One patient (1.5%) developed a plug infection originating from an infected part of the incorporated driveline and, after complete removal, is currently in good condition. No postoperative stroke has been reported after plug implantation. Conclusions: In this European multicentre study, the use of a custom-made titanium plug to close the apical fixation ring after LVAD explantation resulted in a low incidence of plug-related complications. With the volume of patients undergoing LVAD explantations after myocardial recovery increasing, the plug has evolved as a simple alternative to more invasive device explantation procedures or decommissioning with a high risk for infection of the remaining system or stroke.
2022
34
4
683
690
https://pubmed.ncbi.nlm.nih.gov/34888681/
https://academic.oup.com/icvts/article/34/4/683/6458105?login=true
Potapov EV; Politis N; Karck M; Weyand M; Tandler R; Walther T; Emrich F; Reichenspurrner H; Bernhardt A; Barten MJ; Svenarud P; Gummert J; Sef D; Doenst T; Tsyganenko D; Loforte A; Schoenrath F; Falk V.
File in questo prodotto:
File Dimensione Formato  
Plug recovery multicenter.pdf

Accesso aperto

Descrizione: Plug recovery LVAD Multicenter
Tipo di file: PDF EDITORIALE
Dimensione 953.56 kB
Formato Adobe PDF
953.56 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1898092
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact