Introduction: Recently, observational data have raised concerns about safety of selfexpandable (SE) compared to balloon-expandable (BE) valves in TAVI, although potentially limited by patient selection bias. Methods. All Randomized Controlled Trials (RCTs) comparing BE vs. SE TAVI or/and vs. aortic valve replacement (AVR) were included and compared through Network Meta Analysis (NMA). All-cause and cardiovascular (CV) mortality were the primary endpoints, stroke, rates of permanent pacemaker implantation (PPI), moderate/severe paravalvular leak (PVL) and reintervention were the secondary endpoints. Results We obtained data from 11 RCTs, encompassing 9752 patients. After one and two years, no significant differences for allcause and CV mortality were observed. Compared to surgical bioprostheses, both BE and SE TAVI reduced the risk of acute kidney injury (OR 0.42; CI 95% 0.30–0.60 and OR 0.44; CI 95% 0.32–0.60), new-onset atrial fibrillation (OR 0.24; CI 95% 0.14–0.42 and OR 0.21; CI 95% 0.13–0.34) and major bleedings (OR 0.32; CI 95% 0.16–0.65 and OR 0.47; CI 95% 0.25–0.89). The BE prostheses reduced the risk of moderate/severe PVL at 30-day (OR 0.31; CI 95% 0.17–0.55) and of PPI both at 30-day (OR 0.51; CI 95% 0.33–0.79) and 1 year (OR 0.40; CI 95% 0.30–0.55) as compared to SE TAVI. Conclusions A TAVI strategy, independently from BE or SE prostheses, offers a midterm survival comparable to AVR. The BE prostheses are associated with a reduction of PPI and PVL compared to SE prostheses without any differences in all-cause and CV mortality during two years of follow up. PROSPERO ID CRD42020182407.

Aortic valve replacement vs. balloon-expandable and self-expandable transcatheter implantation: A network meta-analysis

D'Ascenzo F.;Bruno F.;De Filippo O.;Breviario S.;Franchin L.;Gallone G.;Rinaldi M.;Conrotto F.;Salizzoni S.;De Ferrari G. M.
2021-01-01

Abstract

Introduction: Recently, observational data have raised concerns about safety of selfexpandable (SE) compared to balloon-expandable (BE) valves in TAVI, although potentially limited by patient selection bias. Methods. All Randomized Controlled Trials (RCTs) comparing BE vs. SE TAVI or/and vs. aortic valve replacement (AVR) were included and compared through Network Meta Analysis (NMA). All-cause and cardiovascular (CV) mortality were the primary endpoints, stroke, rates of permanent pacemaker implantation (PPI), moderate/severe paravalvular leak (PVL) and reintervention were the secondary endpoints. Results We obtained data from 11 RCTs, encompassing 9752 patients. After one and two years, no significant differences for allcause and CV mortality were observed. Compared to surgical bioprostheses, both BE and SE TAVI reduced the risk of acute kidney injury (OR 0.42; CI 95% 0.30–0.60 and OR 0.44; CI 95% 0.32–0.60), new-onset atrial fibrillation (OR 0.24; CI 95% 0.14–0.42 and OR 0.21; CI 95% 0.13–0.34) and major bleedings (OR 0.32; CI 95% 0.16–0.65 and OR 0.47; CI 95% 0.25–0.89). The BE prostheses reduced the risk of moderate/severe PVL at 30-day (OR 0.31; CI 95% 0.17–0.55) and of PPI both at 30-day (OR 0.51; CI 95% 0.33–0.79) and 1 year (OR 0.40; CI 95% 0.30–0.55) as compared to SE TAVI. Conclusions A TAVI strategy, independently from BE or SE prostheses, offers a midterm survival comparable to AVR. The BE prostheses are associated with a reduction of PPI and PVL compared to SE prostheses without any differences in all-cause and CV mortality during two years of follow up. PROSPERO ID CRD42020182407.
2021
337
-
90
98
Aortic stenosis; Balloon-expandable valves; Self-expandable valves; Surgical aortic valve implantation; Transcatheter aortic valve implantation
D'Ascenzo F.; Bruno F.; Baldetti L.; De Filippo O.; Marengo G.; Breviario S.; Melillo F.; Thyregod H.G.H.; Thiele H.; Sondergaard L.; Popma J.J.; Koda...espandi
File in questo prodotto:
File Dimensione Formato  
PMID_33974961.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1904267
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 15
social impact