The accuracy of French medico-administrative data concerning amyotrophic lateral sclerosis (ALS) is to date unknown. We aimed to assess the validity of hospital discharge data (HDD) and health insurance data (HID) related to ALS. A retrospective population-based study was performed. The French register of ALS in Limousin (FRALim) was used as gold standard (2000-2013 period). All patients discharged from the regional hospitals with a 'G12.2' code in their HDD (according to the International Classification of Disease-10th version) or having a G12 HID code were considered. In the study period, the register included a total of 322 incident ALS patients. Among 451 subjects identified through HDD, 290 were true incident ALS cases, corresponding to 90.1% (95% CI 86.3-93.1) sensitivity and 64.3% (95% CI 59.7-68.7) positive predictive value (PPV). A total of 184 subjects were identified through HID, 142 of which were true ALS cases. This corresponded to 44.1% (95% CI 38.6-49.7) sensitivity and 75.5% (95% CI 68.7-81.5) PPV. The combination of both HDD and HID led to 93.8% (95% CI 90.6-96.2) sensitivity and 60.8% (95% CI 56.3-65.1) PPV. This study shows that French HDD and HID, even if combined, are not per se suitable for accurate and exhaustive direct identification of ALS cases.

Validity of medico-administrative data related to amyotrophic lateral sclerosis in France: A population-based study

Vasta, Rosario;
2017-01-01

Abstract

The accuracy of French medico-administrative data concerning amyotrophic lateral sclerosis (ALS) is to date unknown. We aimed to assess the validity of hospital discharge data (HDD) and health insurance data (HID) related to ALS. A retrospective population-based study was performed. The French register of ALS in Limousin (FRALim) was used as gold standard (2000-2013 period). All patients discharged from the regional hospitals with a 'G12.2' code in their HDD (according to the International Classification of Disease-10th version) or having a G12 HID code were considered. In the study period, the register included a total of 322 incident ALS patients. Among 451 subjects identified through HDD, 290 were true incident ALS cases, corresponding to 90.1% (95% CI 86.3-93.1) sensitivity and 64.3% (95% CI 59.7-68.7) positive predictive value (PPV). A total of 184 subjects were identified through HID, 142 of which were true ALS cases. This corresponded to 44.1% (95% CI 38.6-49.7) sensitivity and 75.5% (95% CI 68.7-81.5) PPV. The combination of both HDD and HID led to 93.8% (95% CI 90.6-96.2) sensitivity and 60.8% (95% CI 56.3-65.1) PPV. This study shows that French HDD and HID, even if combined, are not per se suitable for accurate and exhaustive direct identification of ALS cases.
2017
18
1-2
24
31
Amyotrophic lateral sclerosis; administrative database research; epidemiology; hospital morbidity data; insurance data; positive predictive value; sensitivity
Vasta, Rosario; Boumédiene, Farid; Couratier, Philippe; Nicol, Marie; Nicoletti, Alessandra; Preux, Pierre-Marie; Marin, Benoit
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1904340
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact