In this paper, we assess the performances of different analytical prescriptions for the effective-one-body (EOB) radiation reaction along generic planar orbits using exact numerical result in the test-mass limit. We consider three prescriptions put forward in the recent literature: (i) the quasicircular prescription (QC), (ii) the QC with second post-Newtonian (2PN) order noncircular corrections (QC2PN), and (iii) the QC corrected by the noncircular Newtonian prefactor (NCN). The analytical fluxes are then compared against the exact fluxes that are computed by solving the Teukolsky equation with a test-mass source in geodesic motion. We find that the NCN prescription is the most accurate for both eccentric and hyperbolic orbits, and it is in robust agreement also for large values of the eccentricity. This result carries over to the comparable masses, as we discuss for a numerical-relativity (NR) case study. We also demonstrate that, while the EOB/NR waveform unfaithfulness is a necessary check for the precision of EOB models, the direct comparison of EOB/NR fluxes is a more stringent and informative test to select the best prescription. Finally, we propose an improved radiation reaction, NCN2PN, that includes noncircular 2PN corrections, in resummed form, as a further multiplicative contribution and that is valid for any mass ratio.

Assessment of effective-one-body radiation reactions for generic planar orbits

Simone Albanesi;
2022-01-01

Abstract

In this paper, we assess the performances of different analytical prescriptions for the effective-one-body (EOB) radiation reaction along generic planar orbits using exact numerical result in the test-mass limit. We consider three prescriptions put forward in the recent literature: (i) the quasicircular prescription (QC), (ii) the QC with second post-Newtonian (2PN) order noncircular corrections (QC2PN), and (iii) the QC corrected by the noncircular Newtonian prefactor (NCN). The analytical fluxes are then compared against the exact fluxes that are computed by solving the Teukolsky equation with a test-mass source in geodesic motion. We find that the NCN prescription is the most accurate for both eccentric and hyperbolic orbits, and it is in robust agreement also for large values of the eccentricity. This result carries over to the comparable masses, as we discuss for a numerical-relativity (NR) case study. We also demonstrate that, while the EOB/NR waveform unfaithfulness is a necessary check for the precision of EOB models, the direct comparison of EOB/NR fluxes is a more stringent and informative test to select the best prescription. Finally, we propose an improved radiation reaction, NCN2PN, that includes noncircular 2PN corrections, in resummed form, as a further multiplicative contribution and that is valid for any mass ratio.
2022
105
10
1
22
General Relativity and Quantum Cosmology
Simone Albanesi; Alessandro Nagar; Sebastiano Bernuzzi; Andrea Placidi; Marta Orselli
File in questo prodotto:
File Dimensione Formato  
PhysRevD.105.104031.pdf

Accesso riservato

Dimensione 7.36 MB
Formato Adobe PDF
7.36 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1931085
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 6
social impact