Aim: Coronary sinus (CS) reducer implantation is associated with symptomatic relief of patients with refractory angina. However, 15% to 30% of the patients do not respond to this treatment. Aim if this study was to evaluate the effect of CS size in the effectiveness of the device. Methods: Prior to device implantation and at 4-month resting ventricular function was assessed by stress cardiac magnetic resonance. Ischemia was assessed by the myocardial perfusion reserve index (MPRI). Results: Fifteen patients (66 ± 10 years) underwent successful CS Reducer implantation, with improvements in angina class and exercise tolerance. Patients with a smaller CS size (<5.8 mm) presented a significantly higher percentage increase in MPRI (63 ± 51 vs 9 ± 30%, P =.03) and a higher reduction in left ventricle end-diastolic volumes. Conclusions: Greater benefits, in terms of ischemia improvement, after CS Reducer implantation were seen in patients with smaller CS sizes, suggesting a potential mechanism underlying the observed rates of reducer non-responsiveness.

Coronary sinus size and ischemia improvement after reducer implantation; “one size to fit them all?”

Gallone G.;Beneduce A.;Giannini F.
2021-01-01

Abstract

Aim: Coronary sinus (CS) reducer implantation is associated with symptomatic relief of patients with refractory angina. However, 15% to 30% of the patients do not respond to this treatment. Aim if this study was to evaluate the effect of CS size in the effectiveness of the device. Methods: Prior to device implantation and at 4-month resting ventricular function was assessed by stress cardiac magnetic resonance. Ischemia was assessed by the myocardial perfusion reserve index (MPRI). Results: Fifteen patients (66 ± 10 years) underwent successful CS Reducer implantation, with improvements in angina class and exercise tolerance. Patients with a smaller CS size (<5.8 mm) presented a significantly higher percentage increase in MPRI (63 ± 51 vs 9 ± 30%, P =.03) and a higher reduction in left ventricle end-diastolic volumes. Conclusions: Greater benefits, in terms of ischemia improvement, after CS Reducer implantation were seen in patients with smaller CS sizes, suggesting a potential mechanism underlying the observed rates of reducer non-responsiveness.
2021
98
3
365
369
cardiac magnetic resonance; coronary sinus reducer; myocardial ischemia; non-responders; refractory angina
Tzanis G.; Khokhar A.A.; Ponticelli F.; Gallone G.; Palmisano A.; Esposito A.; Beneduce A.; Guarracini S.; Colombo A.; Giannini F.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1942422
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact