Aims: The aim of this study was to evaluate the impact of a horizontal aorta (HA) on device success and short-term clinical outcomes of transcatheter aortic valve implantation (TAVI). Methods and results: We retrospectively assessed 547 consecutive patients treated with transfemoral second-generation non-balloon-expandable (NBE) (n=447) and balloon-expandable (BE) (n=100) TAVI for symptomatic severe aortic stenosis. Aortic angulation (AA) was evaluated with preprocedural computed tomography. Patients were dichotomised according to a previously established AA cut-point: HA group (AA ≥48°, n=230) and normal aorta (NA) group (AA <48°, n=317). Endpoints were considered according to the Valve Academic Research Consortium-2 definitions. Fluoroscopy time (32.8±16.4 vs 30.3±13.9 minutes, p=0.060) and radiation dose (kerma area product 120.8±99.7 vs 103.7±81.1 Gy·cm2, p=0.033) were higher in the HA group as compared to the NA group. No difference in device success was observed between patients with and without an HA (88.3% vs 88.0%, p=0.929). No differences in device success and 30-day outcomes were observed when comparing HA and NA patients, according to BE and NBE prostheses. Conclusions: The presence of an HA has no impact on device success and short-term clinical outcomes of TAVI with either second-generation NBE or BE devices.

Impact of horizontal aorta on procedural and clinical outcomes in second-generation transcatheter aortic valve implantation

Gallone G.;Giannini F.
2019-01-01

Abstract

Aims: The aim of this study was to evaluate the impact of a horizontal aorta (HA) on device success and short-term clinical outcomes of transcatheter aortic valve implantation (TAVI). Methods and results: We retrospectively assessed 547 consecutive patients treated with transfemoral second-generation non-balloon-expandable (NBE) (n=447) and balloon-expandable (BE) (n=100) TAVI for symptomatic severe aortic stenosis. Aortic angulation (AA) was evaluated with preprocedural computed tomography. Patients were dichotomised according to a previously established AA cut-point: HA group (AA ≥48°, n=230) and normal aorta (NA) group (AA <48°, n=317). Endpoints were considered according to the Valve Academic Research Consortium-2 definitions. Fluoroscopy time (32.8±16.4 vs 30.3±13.9 minutes, p=0.060) and radiation dose (kerma area product 120.8±99.7 vs 103.7±81.1 Gy·cm2, p=0.033) were higher in the HA group as compared to the NA group. No difference in device success was observed between patients with and without an HA (88.3% vs 88.0%, p=0.929). No differences in device success and 30-day outcomes were observed when comparing HA and NA patients, according to BE and NBE prostheses. Conclusions: The presence of an HA has no impact on device success and short-term clinical outcomes of TAVI with either second-generation NBE or BE devices.
2019
15
9
746
756
Aortic stenosis; MSCT; TAVI
Di Stefano D.; Colombo A.; Mangieri A.; Gallone G.; Tzanis G.; Laricchia A.; Baldetti L.; Palmisano A.; Esposito A.; Gallo F.; Latib A.; Montorfano M.; Giannini F.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1942423
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? ND
social impact