To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10^34 cm^−2 s^−1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionising energy loss of up to Φeq = 3.5 × 10^16 cm^−2. This paper focuses on planar pixel sensor design and qualification up to a fluence of Φeq = 1.4 × 10^16 cm^−2. For the development of appropriate planar pixel sensors an R&D program was initiated, which includes n+ p sensors on 150 mm (6'') wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm^2 and 50 × 50 μm^2 manufactured by Hamamatsu Photonics K.K. (HPK). Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfil the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm^2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to Φeq = 7.2 × 10^15 cm^−2.

Evaluation of HPK n+-p planar pixel sensors for the CMS Phase-2 upgrade

Bellan R.;Costa M.;Covarelli R.;Grippo M.;Luongo F.;Mecca A.;Migliore E.;Pacher L.;Tarricone C.;Vagnerini A.;
2023-01-01

Abstract

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10^34 cm^−2 s^−1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionising energy loss of up to Φeq = 3.5 × 10^16 cm^−2. This paper focuses on planar pixel sensor design and qualification up to a fluence of Φeq = 1.4 × 10^16 cm^−2. For the development of appropriate planar pixel sensors an R&D program was initiated, which includes n+ p sensors on 150 mm (6'') wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm^2 and 50 × 50 μm^2 manufactured by Hamamatsu Photonics K.K. (HPK). Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfil the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm^2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to Φeq = 7.2 × 10^15 cm^−2.
2023
1053
articolo 168326
1
18
https://www.sciencedirect.com/science/article/pii/S0168900223003169?via=ihub
Adam W.; Bergauer T.; Damanakis K.; Dragicevic M.; Fruhwirth R.; Steininger H.; Beaumont W.; Darwish M.R.; Janssen T.; Kello T.; Sfar H.R.; Van Mechel...espandi
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0168900223003169-main.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 2.86 MB
Formato Adobe PDF
2.86 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1951211
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 0
social impact