To carry out effective and quick identification of SARS-CoV-2 from nasopharyngeal swabs and contain outbreaks, reliable and rapid tools are needed. Herein, we compared a rapid antigen test based on active microfluidic technology to an RT-qPCR assay in pediatric and young adult patients admitted to the Pediatric Emergency Unit of a Children’s Hospital. Nasopharyngeal swabs collected from patients with suspected COVID-19 disease and from those without COVID-19 related symptoms, but requiring hospitalization, were performed with both antigen test and RT-qPCR assays. We included 375 patients with a median age of 5 years in the study, with an estimated overall prevalence of 7.2%. Overall, we observed a specificity of 97.4% (95% CI: 94.9–98.7) and a sensitivity of 66.6% (95% CI: 46.0–82.7) with a positive likelihood ratio (LR+) of 25.8 (95% CI: 12.8–51.8). In the subgroup of symptomatic patients, the specificity and the sensitivity were 95.2% (95% CI: 89.4–98.0) and 80.0% (95% CI: 44.2–96.5) respectively; LR+ was 16.6 (95% CI: 7.19–38.6). In the asymptomatic subset, the performance showed a specificity of 98.7% (95% CI: 95.8–99.7), a sensitivity of 58.8% (95% CI: 33.5–80.6), and an LR+ of 43.7 (95% CI: 13.3–144.0). Compared to RT-qPCR, the new microfluidic-based antigen test showed higher specificity (>95%) in the pediatric population, thus representing a suitable point-of-care testing (POCT) in a clinical setting with low prevalence of COVID-19.

Application of a SARS-CoV-2 Antigen Rapid Immunoassay Based on Active Microfluidic Technology in a Setting of Children and Young Adults

Bottino P.;
2024-01-01

Abstract

To carry out effective and quick identification of SARS-CoV-2 from nasopharyngeal swabs and contain outbreaks, reliable and rapid tools are needed. Herein, we compared a rapid antigen test based on active microfluidic technology to an RT-qPCR assay in pediatric and young adult patients admitted to the Pediatric Emergency Unit of a Children’s Hospital. Nasopharyngeal swabs collected from patients with suspected COVID-19 disease and from those without COVID-19 related symptoms, but requiring hospitalization, were performed with both antigen test and RT-qPCR assays. We included 375 patients with a median age of 5 years in the study, with an estimated overall prevalence of 7.2%. Overall, we observed a specificity of 97.4% (95% CI: 94.9–98.7) and a sensitivity of 66.6% (95% CI: 46.0–82.7) with a positive likelihood ratio (LR+) of 25.8 (95% CI: 12.8–51.8). In the subgroup of symptomatic patients, the specificity and the sensitivity were 95.2% (95% CI: 89.4–98.0) and 80.0% (95% CI: 44.2–96.5) respectively; LR+ was 16.6 (95% CI: 7.19–38.6). In the asymptomatic subset, the performance showed a specificity of 98.7% (95% CI: 95.8–99.7), a sensitivity of 58.8% (95% CI: 33.5–80.6), and an LR+ of 43.7 (95% CI: 13.3–144.0). Compared to RT-qPCR, the new microfluidic-based antigen test showed higher specificity (>95%) in the pediatric population, thus representing a suitable point-of-care testing (POCT) in a clinical setting with low prevalence of COVID-19.
2024
16
1
1
8
COVID-19; microfluidic; pediatric emergency medicine; POCT; SARS-CoV-2
Leli C.; Ferrara L.; Bottino P.; Bara C.; Megna I.; Penpa S.; Felici E.; Maconi A.; Rocchetti A.
File in questo prodotto:
File Dimensione Formato  
viruses-16-00041-v2.pdf

Accesso aperto

Dimensione 720.73 kB
Formato Adobe PDF
720.73 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1973070
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact