Vitamin D (Vit D) is a fat-soluble molecule acting like a hormone, and it is involved in several biological mechanisms such as gene expression, calcium homeostasis, bone metabolism, immune modulation, viral protection, and neuromuscular functions. Vit D deficiency can lead to chronic hypocalcemia, hyperparathyroidism, and many other pathological conditions; in this context, low and very low levels of 25-hydroxy-vitamin D (25-OH-D) were found to be associated with an increased risk of COVID-19 infection and the likelihood of many severe diseases. For all these reasons, it is important to quantify and monitor 25-OH-D levels to ensure that the serum/blood concentrations are not clinically suboptimal. Serum concentration of 25-OH-D is currently the main indicator of Vit D status, and it is currently performed by different assays, but the most common quantitation techniques involve immunometric methods or chromatography. Nevertheless, other quantitation techniques and instruments are now emerging, such as AFIAS-1 (R) and AFIAS-10 (R) (Boditech and Menarini) based on the immunofluorescence analyzer, that guarantee an automated system with cartridges able to give quick and reliable results as a point-of-care test (POCT). This work aims to compare AFIAS-1 (R) and AFIAS-10 (R) (Boditech and Menarini) Vit D quantitation with Ultra High-Performance Liquid Chromatography coupled with tandem mass spectrometry that currently represents the gold standard technique for Vit D quantitation. The analyses were performed in parallel on 56 samples and in different conditions (from fresh and frozen plasma) to assess the reliability of the results. Any statistically significant differences in methods, the fixed error, and the error proportional to concentration were reported. Results obtained in all conditions showed a good correlation between both AFIAS (R) instruments and LC-MS/MS, and we can affirm that AFIAS-1 (R) and AFIAS-10 (R) are reliable instruments for measuring 25-OH-D with accuracy and in a fast manner.

Comparative Performance Assessment of Novel Fluorescence Immunoassay POCTs for Measuring Circulating Levels of Vitamin-D

Palermiti, Alice
;
Manca, Alessandra;Maiese, Domenico;Antonucci, Miriam;Simiele, Marco;De Nicolo, Amedeo
Co-last
;
D'Avolio, Antonio
Co-last
2024-01-01

Abstract

Vitamin D (Vit D) is a fat-soluble molecule acting like a hormone, and it is involved in several biological mechanisms such as gene expression, calcium homeostasis, bone metabolism, immune modulation, viral protection, and neuromuscular functions. Vit D deficiency can lead to chronic hypocalcemia, hyperparathyroidism, and many other pathological conditions; in this context, low and very low levels of 25-hydroxy-vitamin D (25-OH-D) were found to be associated with an increased risk of COVID-19 infection and the likelihood of many severe diseases. For all these reasons, it is important to quantify and monitor 25-OH-D levels to ensure that the serum/blood concentrations are not clinically suboptimal. Serum concentration of 25-OH-D is currently the main indicator of Vit D status, and it is currently performed by different assays, but the most common quantitation techniques involve immunometric methods or chromatography. Nevertheless, other quantitation techniques and instruments are now emerging, such as AFIAS-1 (R) and AFIAS-10 (R) (Boditech and Menarini) based on the immunofluorescence analyzer, that guarantee an automated system with cartridges able to give quick and reliable results as a point-of-care test (POCT). This work aims to compare AFIAS-1 (R) and AFIAS-10 (R) (Boditech and Menarini) Vit D quantitation with Ultra High-Performance Liquid Chromatography coupled with tandem mass spectrometry that currently represents the gold standard technique for Vit D quantitation. The analyses were performed in parallel on 56 samples and in different conditions (from fresh and frozen plasma) to assess the reliability of the results. Any statistically significant differences in methods, the fixed error, and the error proportional to concentration were reported. Results obtained in all conditions showed a good correlation between both AFIAS (R) instruments and LC-MS/MS, and we can affirm that AFIAS-1 (R) and AFIAS-10 (R) are reliable instruments for measuring 25-OH-D with accuracy and in a fast manner.
2024
Inglese
Esperti anonimi
29
7
1636
1644
9
25-OH-Vitamin D; point-of-care test; quantitation technique
no
1 – prodotto con file in versione Open Access (allegherò il file al passo 6 - Carica)
262
9
Palermiti, Alice; Manca, Alessandra; Mastrantonio, Fabrizio; Maiese, Domenico; Curatolo, Aurora; Antonucci, Miriam; Simiele, Marco; De Nicolo, Amedeo;...espandi
info:eu-repo/semantics/article
open
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
File Dimensione Formato  
molecules-29-01636.pdf

Accesso aperto

Tipo di file: PDF EDITORIALE
Dimensione 2.01 MB
Formato Adobe PDF
2.01 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1975071
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact