In multi-electrode devices, charge pulses at all the electrodes are induced concurrently by the motion of the excess charge carriers generated by a single ion. This charge-sharing effect is such that the pulse amplitude at each sensitive electrode depends on the device geometry, its overall electrostatic configuration, and the charge transport properties of the detecting material. Therefore, the cross-analysis of the charge pulses induced at each electrode offers implicit information on the position of the ion impact. In this work, we investigate the two-dimensional position sensitivity of a diamond detector fabricated by deep ion beam lithography. By exploiting the ion beam induced charge technique, the device was exposed to a 2 MeV Li+ ion micro-beam to map the spatial dependence of the charge collection efficiency (CCE) on the nominal micro-beam scanning position. The combination of the CCE maps revealed a two-dimensional position sensitivity of the device with micrometric resolution at the center of the active region.

A multi-electrode two-dimensional position sensitive diamond detector

Ditalia Tchernij, S.
First
;
Siciliano, D.;Forneris, J.
;
Picollo, F.;Campostrini, M.;Siketic, Z.;Jaksic, M.;Vittone, E.
Last
2024-01-01

Abstract

In multi-electrode devices, charge pulses at all the electrodes are induced concurrently by the motion of the excess charge carriers generated by a single ion. This charge-sharing effect is such that the pulse amplitude at each sensitive electrode depends on the device geometry, its overall electrostatic configuration, and the charge transport properties of the detecting material. Therefore, the cross-analysis of the charge pulses induced at each electrode offers implicit information on the position of the ion impact. In this work, we investigate the two-dimensional position sensitivity of a diamond detector fabricated by deep ion beam lithography. By exploiting the ion beam induced charge technique, the device was exposed to a 2 MeV Li+ ion micro-beam to map the spatial dependence of the charge collection efficiency (CCE) on the nominal micro-beam scanning position. The combination of the CCE maps revealed a two-dimensional position sensitivity of the device with micrometric resolution at the center of the active region.
2024
Inglese
Esperti anonimi
124
22
1
8
8
https://doi.org/10.1063/5.0205621
Spatial dependence, Ion beam induced charge, Electrodes, Ion implantation, Ion beam lithography, Semiconductor detectors, Radiation detectors, Charge transport
CROAZIA
   FORNERIS J. - "QADET: Quantum Sensors for Metrology Based on Single-Atom-Like Device Technology" - 20IND05 - Cdd 10/06/2021
   QADeT
   EUROPEAN COMMISSION
   H2020
   20IND05

   Compagnia di San Paolo - Bando ex-post - Anno 2020 - "Deterministic Fabrication of Fock State Sources" - Cda 21/12/2021
   D-FOCK
   COMPAGNIA DI SAN PAOLO
   FORNERIS J.
1 – prodotto con file in versione Open Access (allegherò il file al passo 6 - Carica)
262
10
Ditalia Tchernij, S.; Siciliano, D.; Provatas, G.; Forneris, J.; Picollo, F.; Campostrini, M.; Rigato, V.; Siketic, Z.; Jaksic, M.; Vittone, E....espandi
info:eu-repo/semantics/article
open
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
File Dimensione Formato  
223502_1_5.0205621.pdf

Accesso aperto

Descrizione: Versione open access
Tipo di file: PDF EDITORIALE
Dimensione 2.38 MB
Formato Adobe PDF
2.38 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1984051
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact