IntroductionAmong different coronary stents implanted in High Bleeding Risk (HBR) patients with an indication for short antiplatelet therapy, no comparisons in terms of efficacy have been provided.MethodsA Network Meta Analysis was performed including all randomized controlled trials comparing different coronary stents evaluated in HBR patients. Major Adverse Cardiovascular Events (MACEs) as defined by each included trial were the primary end point, whereas TLR (target lesion revascularization), TVR (target vessel revascularization), stent thrombosis and total and major (BARC3-5) bleedings were the secondary ones.ResultsA total of four studies (ONYX ONE, LEADERS FREE, SENIOR and HBR in BIO-RESORT) including 6637 patients were analyzed with different kind of stents and dual antiplatelet therapy (DAPT) length (1 or 6 months) on 12 months follow-up. About one-third of these patients were defined HBR due to indication for oral anticoagulation. All drug eluting stents (DESs) reduced risk of MACE compared to Bare Metal Stents (BMSs) when followed by a 1-month DAPT. At SUCRA analysis, Orsiro was the device with the highest probability of performing best. Rates of TLR and TVR were significantly lower when using Resolute Onyx, Synergy and BioFreedom stents in comparison to BMS when followed by 1-month DAPT, with Synergy ranking best. Synergy also showed a significantly lower number of stent thrombosis compared to BMS (RR 0.28, 95% CI 0.06-0.93), while Orsiro and Resolute Integrity showed the highest probability of performing best.ConclusionIn HBRs patients, all DESs were superior to BMSs in terms of efficacy and safety. Among DESs, Orsiro was the one with the highest ranking in terms of MACE, mainly driven by a reduced incidence of repeated revascularization and stent thrombosis

Safety and efficacy of drug‐eluting stents for patients at high risk of bleedings: A network meta‐analysis

Giacobbe, Federico
Co-first
;
Valente, Eduardo
Co-first
;
Morena, Arianna;Nebiolo, Marco;Giannino, Giuseppe;De Filippo, Ovidio
;
Isaevska, Elena;Richiardi, Lorenzo;Iannaccone, Mario;Zoccai, Giuseppe Biondi;D'Ascenzo, Fabrizio;Ferrari, Gaetano Maria De
Last
2024-01-01

Abstract

IntroductionAmong different coronary stents implanted in High Bleeding Risk (HBR) patients with an indication for short antiplatelet therapy, no comparisons in terms of efficacy have been provided.MethodsA Network Meta Analysis was performed including all randomized controlled trials comparing different coronary stents evaluated in HBR patients. Major Adverse Cardiovascular Events (MACEs) as defined by each included trial were the primary end point, whereas TLR (target lesion revascularization), TVR (target vessel revascularization), stent thrombosis and total and major (BARC3-5) bleedings were the secondary ones.ResultsA total of four studies (ONYX ONE, LEADERS FREE, SENIOR and HBR in BIO-RESORT) including 6637 patients were analyzed with different kind of stents and dual antiplatelet therapy (DAPT) length (1 or 6 months) on 12 months follow-up. About one-third of these patients were defined HBR due to indication for oral anticoagulation. All drug eluting stents (DESs) reduced risk of MACE compared to Bare Metal Stents (BMSs) when followed by a 1-month DAPT. At SUCRA analysis, Orsiro was the device with the highest probability of performing best. Rates of TLR and TVR were significantly lower when using Resolute Onyx, Synergy and BioFreedom stents in comparison to BMS when followed by 1-month DAPT, with Synergy ranking best. Synergy also showed a significantly lower number of stent thrombosis compared to BMS (RR 0.28, 95% CI 0.06-0.93), while Orsiro and Resolute Integrity showed the highest probability of performing best.ConclusionIn HBRs patients, all DESs were superior to BMSs in terms of efficacy and safety. Among DESs, Orsiro was the one with the highest ranking in terms of MACE, mainly driven by a reduced incidence of repeated revascularization and stent thrombosis
2024
103
6
843
855
High Bleeding Risk; drug eluting stents; meta‐analysis; percutaneous coronary intervention
Giacobbe, Federico; Valente, Eduardo; Morena, Arianna; Nebiolo, Marco; Giannino, Giuseppe; De Filippo, Ovidio; Bruno, Francesco; Isaevska, Elena; Rich...espandi
File in questo prodotto:
File Dimensione Formato  
Cathet Cardio Intervent - 2024 - Giacobbe - Safety and efficacy of drug‐eluting stents for patients at high risk of (1).pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 2.3 MB
Formato Adobe PDF
2.3 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2007453
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact