The use of gamma irradiation technologies generates a number of complex scientific and technical problems; for example, the target is manually loaded onto turntables and is rotated during the entire irradiation process and the MCNPX three-dimensional geometry simulation is kept static. For this, it is necessary to introduce additional approaches. In this paper, two new methodologies are proposed for the simulation of irradiation process in panoramic gamma irradiator. The study was performed at the gamma irradiation facility at the Nuclear Technology Development Center of the National Nuclear Energy Commission, Brazil. The source can be reproduced with a homogenized geometry. Validation of MCNPX calculations of gamma doses were performed by thorough comparison with the experimental measurements. The contribution of this proposed source models has opened new lines of research. The results of this study showed that the proposed source models effectively represent the irradiation process.

New source models to represent the irradiation process in panoramic gamma irradiator

Milian, F. M.;
2017-01-01

Abstract

The use of gamma irradiation technologies generates a number of complex scientific and technical problems; for example, the target is manually loaded onto turntables and is rotated during the entire irradiation process and the MCNPX three-dimensional geometry simulation is kept static. For this, it is necessary to introduce additional approaches. In this paper, two new methodologies are proposed for the simulation of irradiation process in panoramic gamma irradiator. The study was performed at the gamma irradiation facility at the Nuclear Technology Development Center of the National Nuclear Energy Commission, Brazil. The source can be reproduced with a homogenized geometry. Validation of MCNPX calculations of gamma doses were performed by thorough comparison with the experimental measurements. The contribution of this proposed source models has opened new lines of research. The results of this study showed that the proposed source models effectively represent the irradiation process.
2017
128
175
182
Dose rate; Gamma beam – 127; Gamma irradiation facility; MCNPX; Panoramic irradiator
Gual, Maritza R.; Milian, F. M.; Mesquita, Amir Z.; Pereira, Claubia
File in questo prodotto:
File Dimensione Formato  
2017_New source models to represent the irradiation process in panoramic gamma irradiator.pdf

Accesso aperto

Tipo di file: PDF EDITORIALE
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2024810
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact