Although there are several radionuclides suitable for radiosynoviorthesis (RSO), not all of them can irradiate deeper synovium. Yttrium-90 (Y-90) is the beta radionuclide with more penetration range; therefore, it is predominantly used to treat knees. The aim of this paper is to highlight several dosimetry concepts to compare Y-90 and Sm-153, also discussing the feasibility of implementing a dose planning methodology for both in RSO. The MCNPX Monte Carlo nuclear code version 2.6 was used for calculating S-values from which the activity to be injected into the joint was obtained. This activity is considered sufficient to deliver a 100-Gy absorbed dose in 1 mm of synovial tissue. The simulated mathematical model consisted of a system formed by several cylindrical slabs of 1-mm thickness, aligned consecutively. The different areas of the cylinder base simulate several synovial membrane sizes. The effective treatment range for each radionuclide was also calculated. Quantification of the synovial joint features (synovial thickness and synovial surface) by diagnostic imaging, such as magnetic resonance (MRI) combined with a Monte Carlo simulation, can be used to achieve a treatment planning strategy in RSO with the available radionuclides.

Dosimetry in Radiosynoviorthesis

Mas Milian, Felix;
2018-01-01

Abstract

Although there are several radionuclides suitable for radiosynoviorthesis (RSO), not all of them can irradiate deeper synovium. Yttrium-90 (Y-90) is the beta radionuclide with more penetration range; therefore, it is predominantly used to treat knees. The aim of this paper is to highlight several dosimetry concepts to compare Y-90 and Sm-153, also discussing the feasibility of implementing a dose planning methodology for both in RSO. The MCNPX Monte Carlo nuclear code version 2.6 was used for calculating S-values from which the activity to be injected into the joint was obtained. This activity is considered sufficient to deliver a 100-Gy absorbed dose in 1 mm of synovial tissue. The simulated mathematical model consisted of a system formed by several cylindrical slabs of 1-mm thickness, aligned consecutively. The different areas of the cylinder base simulate several synovial membrane sizes. The effective treatment range for each radionuclide was also calculated. Quantification of the synovial joint features (synovial thickness and synovial surface) by diagnostic imaging, such as magnetic resonance (MRI) combined with a Monte Carlo simulation, can be used to achieve a treatment planning strategy in RSO with the available radionuclides.
2018
114
1
1
6
radiosynoviorthesis; beta particles; Monte Carlo; dosimetry; absorbed dose; beta particles; dose; absorbed; dosimetry; beta; Monte Carlo
Torres Berdeguez, Mirta Barbara; Thomas, Sylvia; Medeiros, Susie; de Sá, Lidia Vasconcellos; Mas Milian, Felix; da Silva, Ademir Xavier...espandi
File in questo prodotto:
File Dimensione Formato  
2018_preprint_dosimetry_in_radiosynoviorthesis__90y_vs__153sm.1.pdf

Accesso aperto

Tipo di file: PREPRINT (PRIMA BOZZA)
Dimensione 417.83 kB
Formato Adobe PDF
417.83 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2024831
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact