Background The combination of highly localized impedance (LI) and contact force (CF) may improve tissue characterization and lesion prediction during radiofrequency (RF) pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Objective We report the outcomes of our acute and long-term clinical evaluation of CF-LI-guided PVI in consecutive AF ablation cases from an international multicenter clinical setting. Methods Three hundred twenty-four consecutive patients from 20 European centers undergoing RF catheter ablation with the Stablepoint (TM) catheter were enrolled in the CHARISMA registry. Of these, 275 had a minimum follow-up of 1 year and were included in the primary analysis. Results The mean procedure duration was 115 +/- 47 min, and the mean fluoroscopy time was 9.9 +/- 6 min. At the end of the procedures, all PVs had been successfully isolated in all study patients. Minor complications were reported in 12 patients (4.4%). At 1 year, 36 (13.1%) patients had had an AF recurrence, and freedom from antiarrhythmic drugs and AF recurrence was achieved in 228 (82.9%) patients. The recurrence rate was higher in patients with persistent AF (21/116, 18.1%) than in those with paroxysmal AF (15/159, 9.4%; p = 0.0459). On multivariate logistic analysis adjusted for baseline confounders, only time > 6 months from first diagnosis of AF to ablation (HR = 2.93, 95%CI 1.03 to 8.36, p = 0.0459) was independently associated with recurrences. Conclusion An ablation strategy for PVI guided by CF-LI technology proved safe and effective and resulted in a low recurrence rate of AF over 1-year follow-up, irrespective of the underlying AF type.

Contact-force local impedance algorithm to guide effective pulmonary vein isolation in AF patients: 1-year outcome from an international multicenter clinical setting

Anselmino, Matteo;
2024-01-01

Abstract

Background The combination of highly localized impedance (LI) and contact force (CF) may improve tissue characterization and lesion prediction during radiofrequency (RF) pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Objective We report the outcomes of our acute and long-term clinical evaluation of CF-LI-guided PVI in consecutive AF ablation cases from an international multicenter clinical setting. Methods Three hundred twenty-four consecutive patients from 20 European centers undergoing RF catheter ablation with the Stablepoint (TM) catheter were enrolled in the CHARISMA registry. Of these, 275 had a minimum follow-up of 1 year and were included in the primary analysis. Results The mean procedure duration was 115 +/- 47 min, and the mean fluoroscopy time was 9.9 +/- 6 min. At the end of the procedures, all PVs had been successfully isolated in all study patients. Minor complications were reported in 12 patients (4.4%). At 1 year, 36 (13.1%) patients had had an AF recurrence, and freedom from antiarrhythmic drugs and AF recurrence was achieved in 228 (82.9%) patients. The recurrence rate was higher in patients with persistent AF (21/116, 18.1%) than in those with paroxysmal AF (15/159, 9.4%; p = 0.0459). On multivariate logistic analysis adjusted for baseline confounders, only time > 6 months from first diagnosis of AF to ablation (HR = 2.93, 95%CI 1.03 to 8.36, p = 0.0459) was independently associated with recurrences. Conclusion An ablation strategy for PVI guided by CF-LI technology proved safe and effective and resulted in a low recurrence rate of AF over 1-year follow-up, irrespective of the underlying AF type.
2024
67
9
2137
2146
Atrial fibrillation; Catheter ablation; Contact force; Lesion formation; Local impedance; PVI
Solimene, Franscesco; Maggio, Ruggero; De Sanctis, Valerio; Escande, William; Malacrida, Maurizio; Stabile, Giuseppe; Zakine, Cyril; Champ-Rigot, Laur...espandi
File in questo prodotto:
File Dimensione Formato  
GEMINI 1y outcome_final draft for iris.docx

Open Access dal 02/08/2025

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 787.17 kB
Formato Microsoft Word XML
787.17 kB Microsoft Word XML Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2032274
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact