Objectives: To assess the incidence (1 year) and the cumulative incidence (3 years) of the condition of patients accruing cumulative effective doses (CED) of ≥ 100 mSv and their variability among different hospitals. To establish and validate a reference level for the CED in patients with recurrent exposures (RERL) and provide a RERL value. Methods: Data of CT exposure was collected in 9 similar hospitals. The database included 294,222 patient*years who underwent 442,278 CT exams in 3 years. The incidence proportion of patients with CED ≥ 100 mSv in a given year (I100;1) and the 3-year cumulative incidence of patients with CED ≥ 100 mSv over 3 consecutive years (I100;3) were calculated and compared among different institutions. Results: I100;1 ranged from a minimum of 0.1% to a maximum of 5.1%. The percentage of recurrent patients was quite uniform among centres ranging from 23 to 38%. The I100;3 ranged from a minimum of 1.1 to 11.4%. There was a strong positive correlation between the third quartile values of yearly CED and yearly incidence (r = 0.90; R2 = 0.81; p < 0.0001). RERL value in our study was found at 34.0 mSv. Conclusion: The management of patients with recurrent exposures is highly variable among hospitals leading to a 50-fold variation in I100;1 and to a tenfold variation in I100;3. RERL could be established and used by taking as a RERL quantity the CED and as a RERL value the 75th percentile of the third quartiles of the distribution of the yearly CED obtained by surveying different hospitals. Clinical relevance statement: This is the first ever multicentre study that quantifies recurrent exposures in terms of incidence and cumulative incidence of patients with CED ≥ 100 mSv. RERL establishment and use could benefit the optimisation of radioprotection of patients with recurrent exposures. Key points: This is the first multicentre study estimating yearly incidence and 3-year cumulative incidence of patients with cumulative effective doses ≥ 100 mSv. In this study, a 50-fold inter centre variation between the maximum (5.1%) and the minimum value (0.1%) of yearly incidence of patients with cumulative effective doses ≥ 100 mSv was reported. The range of the 3-year cumulative incidence extended from 1.1 to 11.4% (a tenfold variation) The third quartile of the yearly cumulative effective doses in a centre showed a strong positive correlation with the yearly incidence of patients with cumulative effective doses ≥ 100 mSv, with a potential of being used to set reference levels for recurrent exposures.

Optimisation of protection in the medical exposure of recurrent adult patients due to computed tomography procedures: development of recurrent exposures reference levels

Berton, Luca;Fonio, Paolo;Rampado, Osvaldo
2024-01-01

Abstract

Objectives: To assess the incidence (1 year) and the cumulative incidence (3 years) of the condition of patients accruing cumulative effective doses (CED) of ≥ 100 mSv and their variability among different hospitals. To establish and validate a reference level for the CED in patients with recurrent exposures (RERL) and provide a RERL value. Methods: Data of CT exposure was collected in 9 similar hospitals. The database included 294,222 patient*years who underwent 442,278 CT exams in 3 years. The incidence proportion of patients with CED ≥ 100 mSv in a given year (I100;1) and the 3-year cumulative incidence of patients with CED ≥ 100 mSv over 3 consecutive years (I100;3) were calculated and compared among different institutions. Results: I100;1 ranged from a minimum of 0.1% to a maximum of 5.1%. The percentage of recurrent patients was quite uniform among centres ranging from 23 to 38%. The I100;3 ranged from a minimum of 1.1 to 11.4%. There was a strong positive correlation between the third quartile values of yearly CED and yearly incidence (r = 0.90; R2 = 0.81; p < 0.0001). RERL value in our study was found at 34.0 mSv. Conclusion: The management of patients with recurrent exposures is highly variable among hospitals leading to a 50-fold variation in I100;1 and to a tenfold variation in I100;3. RERL could be established and used by taking as a RERL quantity the CED and as a RERL value the 75th percentile of the third quartiles of the distribution of the yearly CED obtained by surveying different hospitals. Clinical relevance statement: This is the first ever multicentre study that quantifies recurrent exposures in terms of incidence and cumulative incidence of patients with CED ≥ 100 mSv. RERL establishment and use could benefit the optimisation of radioprotection of patients with recurrent exposures. Key points: This is the first multicentre study estimating yearly incidence and 3-year cumulative incidence of patients with cumulative effective doses ≥ 100 mSv. In this study, a 50-fold inter centre variation between the maximum (5.1%) and the minimum value (0.1%) of yearly incidence of patients with cumulative effective doses ≥ 100 mSv was reported. The range of the 3-year cumulative incidence extended from 1.1 to 11.4% (a tenfold variation) The third quartile of the yearly cumulative effective doses in a centre showed a strong positive correlation with the yearly incidence of patients with cumulative effective doses ≥ 100 mSv, with a potential of being used to set reference levels for recurrent exposures.
2024
34
7
4475
4483
Computed X-ray tomography; Incidence study; Radiation dosimetry; Radiation protection
Bramilla, Marco; Berton, Luca; Balzano, Rosario F.; Cannillo, Barbara; Carriero, Alessandro; Chauvie, Stephane; Gallo, Teresa; Cornacchia, Samantha; C...espandi
File in questo prodotto:
File Dimensione Formato  
fonio bramilla.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 1.12 MB
Formato Adobe PDF
1.12 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2053010
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact