Background: Coronary access (CA) and percutaneous coronary intervention (PCI) might be challenging after valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) with supra-annular self-expanding valves (SS-TAVs) in surgical aortic valves (SAVs). Our study aim was to compare feasibility, predictors, and techniques of CA and PCI following ViV-TAVR with ACURATE neo2 (Boston Scientific, Marlborough, MA) and Evolut PRO+ (Medtronic, Minneapolis, MN). Methods: Fifteen computed tomography (CT)-based patient-specific aortic models were 3-dimensionally (3D) printed and implanted with specific SAVs and with the 2 SS-TAVs with commissural alignment. Two operators attempted CA (n = 120) and PCI (n = 120) of each coronary artery in a pulsatile-flow-simulator, under real catheterization laboratory conditions. The primary endpoints were the rate of successful CA and PCI. Outcomes with different SS-TAVs were directly compared. An internally mounted borescope camera was used to assess procedures. CT of the models was obtained. Results: ACURATE neo2 showed significantly higher rates of successful CA (96.7% vs 75%, P = 0.001) and PCI (98.3% vs 85%, P = 0.008) and was associated with a shorter procedural time compared with Evolut PRO+. Independent predictors of unsuccessful CA and PCI were smaller SAV size and Evolut PRO+. The advantage of ACURATE neo2 was mediated by a larger valve-to-anatomy distance at the top of the leaflet plane (11.3 mm vs 4.8 mm), facilitating more often an external cannulation approach for both CA (36.7% vs 15%, P < 0.001) and PCI (36.7% vs 21.7%, P = 0.013). Conclusions: The rate of successful CA and PCI following ViV-TAVR was higher with ACURATE neo2 compared with Evolut PRO+. The differences in SS-TAVs design affected the cannulation approach and subsequent procedural outcomes.

Coronary Access and PCI after Transcatheter Aortic Valve Replacement With Different Self-Expanding Platforms in Failed Surgical Valves

Giannini, Francesco;Beneduce, Alessandro;Gallone, Guglielmo;
2024-01-01

Abstract

Background: Coronary access (CA) and percutaneous coronary intervention (PCI) might be challenging after valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) with supra-annular self-expanding valves (SS-TAVs) in surgical aortic valves (SAVs). Our study aim was to compare feasibility, predictors, and techniques of CA and PCI following ViV-TAVR with ACURATE neo2 (Boston Scientific, Marlborough, MA) and Evolut PRO+ (Medtronic, Minneapolis, MN). Methods: Fifteen computed tomography (CT)-based patient-specific aortic models were 3-dimensionally (3D) printed and implanted with specific SAVs and with the 2 SS-TAVs with commissural alignment. Two operators attempted CA (n = 120) and PCI (n = 120) of each coronary artery in a pulsatile-flow-simulator, under real catheterization laboratory conditions. The primary endpoints were the rate of successful CA and PCI. Outcomes with different SS-TAVs were directly compared. An internally mounted borescope camera was used to assess procedures. CT of the models was obtained. Results: ACURATE neo2 showed significantly higher rates of successful CA (96.7% vs 75%, P = 0.001) and PCI (98.3% vs 85%, P = 0.008) and was associated with a shorter procedural time compared with Evolut PRO+. Independent predictors of unsuccessful CA and PCI were smaller SAV size and Evolut PRO+. The advantage of ACURATE neo2 was mediated by a larger valve-to-anatomy distance at the top of the leaflet plane (11.3 mm vs 4.8 mm), facilitating more often an external cannulation approach for both CA (36.7% vs 15%, P < 0.001) and PCI (36.7% vs 21.7%, P = 0.013). Conclusions: The rate of successful CA and PCI following ViV-TAVR was higher with ACURATE neo2 compared with Evolut PRO+. The differences in SS-TAVs design affected the cannulation approach and subsequent procedural outcomes.
2024
40
11
2010
2020
Giannini, Francesco; Khokhar, Arif A; Curio, Jonathan; Beneduce, Alessandro; Montonati, Carolina; Fabris, Enrico; Gallo, Francesco; Zlahoda-Huzior, Ad...espandi
File in questo prodotto:
File Dimensione Formato  
2024 - CJC - Coronary Access and PCI after Transcatheter Aortic Valve Replacement With Different Self-Expanding Platforms in Failed Surgical Valves.pdf

Accesso riservato

Dimensione 2.19 MB
Formato Adobe PDF
2.19 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2074691
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact