In this work, we have tested a photocatalytic material consisting of a core of SiO2/Fe3O4 coated with TiO2 (Magnox) for plausible tertiary wastewater treatment. For this, a pilot plant of 45 L equipped with an Ultraviolet light (UVC) lamp was employed to study the degradation of a model contaminant, enrofloxacin (ENR), as well as water disinfection (elimination of Escherichia coli and Clostridium perfringens). The influence of different operational conditions was explored by means of dye (rhodamine-B) decolorization rates, analyzing the effects of photocatalyst quantity, pH and recirculation flow rates. The magnox/UVC process was also compared with other four Advanced Oxidation Processes (AOPs): (i) UVC irradiation alone, (ii) hydrogen peroxide with UVC (H2O2/UVC), (iii) Fenton, and (iv) photo-Fenton. Although UVC irradiation was efficient enough to produce total water disinfection, only when employing the AOPs, significant degradations of ENR were observed, with photo-Fenton being the most efficient process (total enrofloxacin removal in 5 min and c.a. 80% mineralization in 120 min, at pH(0) 2.8). However, Magnox/UVC has shown great pollutant abatement effectiveness under neutral conditions, with the additional advantage of no acid or H2O2 addition, as well as its plausible reuse and simple separation due to its magnetic properties.

Magnetic photocatalyst for wastewater tertiary treatment at pilot plant scale: Disinfection and enrofloxacin abatement

Sciscenko I.
First
;
2021-01-01

Abstract

In this work, we have tested a photocatalytic material consisting of a core of SiO2/Fe3O4 coated with TiO2 (Magnox) for plausible tertiary wastewater treatment. For this, a pilot plant of 45 L equipped with an Ultraviolet light (UVC) lamp was employed to study the degradation of a model contaminant, enrofloxacin (ENR), as well as water disinfection (elimination of Escherichia coli and Clostridium perfringens). The influence of different operational conditions was explored by means of dye (rhodamine-B) decolorization rates, analyzing the effects of photocatalyst quantity, pH and recirculation flow rates. The magnox/UVC process was also compared with other four Advanced Oxidation Processes (AOPs): (i) UVC irradiation alone, (ii) hydrogen peroxide with UVC (H2O2/UVC), (iii) Fenton, and (iv) photo-Fenton. Although UVC irradiation was efficient enough to produce total water disinfection, only when employing the AOPs, significant degradations of ENR were observed, with photo-Fenton being the most efficient process (total enrofloxacin removal in 5 min and c.a. 80% mineralization in 120 min, at pH(0) 2.8). However, Magnox/UVC has shown great pollutant abatement effectiveness under neutral conditions, with the additional advantage of no acid or H2O2 addition, as well as its plausible reuse and simple separation due to its magnetic properties.
2021
13
3
1
12
advanced oxidation process; enrofloxacin degradation; photocatalysis; photo-Fenton; wastewater treatment
Sciscenko I.; Mestre S.; Climent J.; Valero F.; Escudero-Onate C.; Oller I.; Arques A.
File in questo prodotto:
File Dimensione Formato  
water-13-00329.pdf

Accesso aperto

Descrizione: Articolo OA
Tipo di file: PDF EDITORIALE
Dimensione 2.48 MB
Formato Adobe PDF
2.48 MB Adobe PDF Visualizza/Apri
manuscript.v6 revised IS.docx

Accesso aperto

Dimensione 1.38 MB
Formato Microsoft Word XML
1.38 MB Microsoft Word XML Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2108711
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 9
social impact