Objectives: This study aims to assess the impact of three different strategies of best-fit (BF) alignments of virtual casts on the estimation of the accuracy of intraoral scanner (IOS) in complete-arch scans. Methods: A maxillary typodont, modified with an Implant Scan Body (ISB) in the retroincisive area, was digitized using a desktop scanner (SW Optor Lab) to obtain a reference STL file. The typodont was then scanned 10 times using two IOSs (Trios4, Itero). Each STL file obtained from the IOS was superimposed onto the reference cast using three methods in CloudCompare: full-arch BF (BF-full), BF at the starting tooth (BF-tooth), and BF at the ISB (BF-ISB). Discrepancies from the reference were recorded, and trueness and precision were compared for each method. Statistical analysis with the Kruskall-Wallis nonparametric test was performed (α = 0.05). Results: The Kruskall-Wallis test (p <0.05) revealed statistically significant differences in trueness and precision among the alignment methods. Post Hoc multiple comparison test p-values were all below the critical alpha value. Conclusions: Differences in BF methods lead to significantly different accuracy values of IOS complete-arch scans as different virtual casts’ alignment discrepancy. BF-full had the highest accuracy followed by BF-ISB and BF-tooth.

Effect of Virtual Casts Superimposition Strategies on the Estimation of IOS Accuracy in Complete-Arch Scans

Mussano, F;Mosca Balma, A;
2024-01-01

Abstract

Objectives: This study aims to assess the impact of three different strategies of best-fit (BF) alignments of virtual casts on the estimation of the accuracy of intraoral scanner (IOS) in complete-arch scans. Methods: A maxillary typodont, modified with an Implant Scan Body (ISB) in the retroincisive area, was digitized using a desktop scanner (SW Optor Lab) to obtain a reference STL file. The typodont was then scanned 10 times using two IOSs (Trios4, Itero). Each STL file obtained from the IOS was superimposed onto the reference cast using three methods in CloudCompare: full-arch BF (BF-full), BF at the starting tooth (BF-tooth), and BF at the ISB (BF-ISB). Discrepancies from the reference were recorded, and trueness and precision were compared for each method. Statistical analysis with the Kruskall-Wallis nonparametric test was performed (α = 0.05). Results: The Kruskall-Wallis test (p <0.05) revealed statistically significant differences in trueness and precision among the alignment methods. Post Hoc multiple comparison test p-values were all below the critical alpha value. Conclusions: Differences in BF methods lead to significantly different accuracy values of IOS complete-arch scans as different virtual casts’ alignment discrepancy. BF-full had the highest accuracy followed by BF-ISB and BF-tooth.
2024
32
4
369
376
Accuracy; Complete-arch Scans; Extraoral Reference; Intraoral Scanner; Three-Dimensional Superimposition
Grande, F; Mussano, F; Mosca Balma, A; Lepidi, L; Nuytens, P; Mijiritsky, E; Catapano, S
File in questo prodotto:
File Dimensione Formato  
EBSCO-FullText-03_01_2026.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 3.5 MB
Formato Adobe PDF
3.5 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2128554
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact