The objective of the present work was to establish a simple and appropriated method for the quantification of thiol groups standing on the surface of core-shell nanoparticles elaborated with poly(isobutyl cyanoacrylates) and thiolated chitosan. A critical analysis of the widely used Ellman's method for the determination of thiol groups in various compounds was made. The reduced solubility of the thiolated polymer at the optimal pH of the Ellman's assay (pH 8-8.5) made difficult the accessibility of the Ellman's reagent to thiol groups in the cross-linked polymer. Furthermore, the lack of stability of the Ellman's reaction with time lead to the conclusion that the Ellman's method was of limited value to evaluate thiol groups in thiolated polymers like thiolated chitosan. An alternative and very simple thiol quantification method was developed on the bases of the classical iodine titration. The new method allowed the determination of thiol groups in small amount of samples at acidic pH, and the monitoring of the thiol determination kinetic with time. It was successfully applied to the quantification of active thiol groups on the surface of poly(isobutyl cyanoacrylates) nanoparticles coated with thiol chitosan.

Characterization of chitosan thiolation and application to thiol quantification onto nanoparticle surface

ARPICCO, Silvia Maria;
2007-01-01

Abstract

The objective of the present work was to establish a simple and appropriated method for the quantification of thiol groups standing on the surface of core-shell nanoparticles elaborated with poly(isobutyl cyanoacrylates) and thiolated chitosan. A critical analysis of the widely used Ellman's method for the determination of thiol groups in various compounds was made. The reduced solubility of the thiolated polymer at the optimal pH of the Ellman's assay (pH 8-8.5) made difficult the accessibility of the Ellman's reagent to thiol groups in the cross-linked polymer. Furthermore, the lack of stability of the Ellman's reaction with time lead to the conclusion that the Ellman's method was of limited value to evaluate thiol groups in thiolated polymers like thiolated chitosan. An alternative and very simple thiol quantification method was developed on the bases of the classical iodine titration. The new method allowed the determination of thiol groups in small amount of samples at acidic pH, and the monitoring of the thiol determination kinetic with time. It was successfully applied to the quantification of active thiol groups on the surface of poly(isobutyl cyanoacrylates) nanoparticles coated with thiol chitosan.
2007
340
173
181
Surface modified nanoparticles; thiolated chitosan; Ellman's reagent; DNTB; iodine titration
BRAVO-OSUNA I; TEUTONICO D; ARPICCO S; VAUTHIER C; PONCHEL G
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/23019
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 75
  • ???jsp.display-item.citation.isi??? 69
social impact