The aim of this study was to compare 99Tcm-teboroxime and 201T1 myocardial studies with particular regard to the classification of perfusion defects as reversible or fixed. Twenty patients with a history of previous myocardial infarction and suspected effort ischaemia underwent exercise 201T1 scintigraphy with early (4 h) redistribution and reinjection scans, exercise and rest 99Tcm-teboroxime imaging and coronary angiography. Using a qualitative scoring of static planar images, the perfusion defects were classified as reversible or fixed. 201T1 and 99Tcm-teboroxime gave comparable results in the evaluation of the individual vessels (sensitivity 65%, specificity 80% and 85%, respectively). The stress-redistribution 201T1 sequence classified 45 defects as reversible and 28 as fixed, the stress-rest 99Tcm-teboroxime studies classified 47 as reversible and 26 as fixed (NS). The stress-reinjection 201T1 images, however, characterized 64 defects as reversible and nine as fixed (P < 0.005 versus 201T1 redistribution, P < 0.0005 versus 99Tcm-teboroxime rest). In conclusion, this study shows that rest 99Tcm-teboroxime and 201T1 redistribution give comparable results but that significantly more defects are classified as fixed by 99Tcm-teboroxime than by 201T1 if reinjection of the latter tracer is performed.

Evaluation of 99Tcm-teboroxime scintigraphy for the differentiation of reversible from fixed defects: comEvaluation of 99Tcm-teboroxime scintigraphy for the differentiation of reversible from fixed defects: comparison with 201T1 redistribution and reinjection imaging.

BISI, Gianni;
1993-01-01

Abstract

The aim of this study was to compare 99Tcm-teboroxime and 201T1 myocardial studies with particular regard to the classification of perfusion defects as reversible or fixed. Twenty patients with a history of previous myocardial infarction and suspected effort ischaemia underwent exercise 201T1 scintigraphy with early (4 h) redistribution and reinjection scans, exercise and rest 99Tcm-teboroxime imaging and coronary angiography. Using a qualitative scoring of static planar images, the perfusion defects were classified as reversible or fixed. 201T1 and 99Tcm-teboroxime gave comparable results in the evaluation of the individual vessels (sensitivity 65%, specificity 80% and 85%, respectively). The stress-redistribution 201T1 sequence classified 45 defects as reversible and 28 as fixed, the stress-rest 99Tcm-teboroxime studies classified 47 as reversible and 26 as fixed (NS). The stress-reinjection 201T1 images, however, characterized 64 defects as reversible and nine as fixed (P < 0.005 versus 201T1 redistribution, P < 0.0005 versus 99Tcm-teboroxime rest). In conclusion, this study shows that rest 99Tcm-teboroxime and 201T1 redistribution give comparable results but that significantly more defects are classified as fixed by 99Tcm-teboroxime than by 201T1 if reinjection of the latter tracer is performed.
1993
14
520
528
BISI G ;SCIAGRÀ R ;SANTORO GM ;ZERAUSCHEK F ;FAZZINI PF
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/31804
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact