BACKGROUND: The degree which the various reconstruction techniques prevent bile reflux after gastroduodenal surgery has been poorly studied. METHODS: Bile exposure in the intestinal tract just proximal to the jejunal loop was measured with the Bilitec 2000 device for 24 h after gastroduodenal surgery in three groups of patients. Group 1 comprised 24 patients with a 60-cm Henley's loop after total gastrectomy. Group 2 included 31 patients with a 60-cm Roux-en-Y loop after total (22 patients) or subtotal (nine) gastrectomy. Group 3 contained 21 patients with a 60-cm Roux-en-Y loop anastomosed to the proximal duodenum as part of a duodenal switch operation for pathological transpyloric duodenogastric reflux. Bile exposure, measured as the percentage time with bile absorbance greater than 0.25, was classified as nil, within the range of a control population of healthy subjects, or pathological (above the 95th percentile for the control population). Reflux symptoms were scored and all patients had upper gastrointestinal endoscopy. RESULTS: Bile was detected in the intestine proximal to the loop in none of 24 patients in group 1, eight of 31 in group 2 and 12 of 21 in group 3 (P < 0.001). The mean reflux symptom score increased with the degree of bile exposure, and the proportion of patients with oesophagitis or gastritis correlated well with the extent of bile exposure (P < 0.001). CONCLUSION: A long Henley's loop was more effective in preventing bile reflux than a long Roux-en-Y loop. Bilitec data correlated well with the severity of reflux symptoms and the presence of mucosal lesions.

Oesophageal and gastric bile exposure after gastroduodenal surgery with Henley's interposition or a Roux-en-Y loop

ROMAGNOLI, Renato;SALIZZONI, Mauro
2004-01-01

Abstract

BACKGROUND: The degree which the various reconstruction techniques prevent bile reflux after gastroduodenal surgery has been poorly studied. METHODS: Bile exposure in the intestinal tract just proximal to the jejunal loop was measured with the Bilitec 2000 device for 24 h after gastroduodenal surgery in three groups of patients. Group 1 comprised 24 patients with a 60-cm Henley's loop after total gastrectomy. Group 2 included 31 patients with a 60-cm Roux-en-Y loop after total (22 patients) or subtotal (nine) gastrectomy. Group 3 contained 21 patients with a 60-cm Roux-en-Y loop anastomosed to the proximal duodenum as part of a duodenal switch operation for pathological transpyloric duodenogastric reflux. Bile exposure, measured as the percentage time with bile absorbance greater than 0.25, was classified as nil, within the range of a control population of healthy subjects, or pathological (above the 95th percentile for the control population). Reflux symptoms were scored and all patients had upper gastrointestinal endoscopy. RESULTS: Bile was detected in the intestine proximal to the loop in none of 24 patients in group 1, eight of 31 in group 2 and 12 of 21 in group 3 (P < 0.001). The mean reflux symptom score increased with the degree of bile exposure, and the proportion of patients with oesophagitis or gastritis correlated well with the extent of bile exposure (P < 0.001). CONCLUSION: A long Henley's loop was more effective in preventing bile reflux than a long Roux-en-Y loop. Bilitec data correlated well with the severity of reflux symptoms and the presence of mucosal lesions.
2004
91
5
580
585
Henley loop, Roux loop
MABRUT JY; COLLARD JM; ROMAGNOLI R; GUTSCHOW C; SALIZZONI M
File in questo prodotto:
File Dimensione Formato  
Henley vs Roux.pdf

Accesso riservato

Descrizione: Articolo principale
Tipo di file: PDF EDITORIALE
Dimensione 144.62 kB
Formato Adobe PDF
144.62 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/33519
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact