The Ventak CHF/CONTAK CD Biventricular Pacing Study is a prospective randomized trial to examine the safety and efficacy of biventricular (BV) pacing in patients with standard indications for an ICD, symptomatic heart failure, a LVEF < or = 0.35, and a QRS > or = 120 ms. Patients underwent implantation of a BV pacing and sensing system with backup defibrillation capability, which includes a steroid-eluting coronary venous lead that is advanced into the coronary venous vasculature by over-the-wire techniques. LV pacing threshold, BV impedance, and BV R wave amplitude were measured in 58 consecutive patients. Using a percutaneous over-the-wire insertion technique, steroid-eluting coronary venous leads were associated with satisfactory mean LV pacing threshold, BV impedance, and BV R wave amplitude acutely up to 4 months after implantation. Pacing threshold stabilized 2 weeks after lead implantation and sensing threshold remained stable from the time of implant.

Performance of a new steroid-eluting coronary sinus lead designed for left ventricular pacing.

GAITA, Fiorenzo;
2000-01-01

Abstract

The Ventak CHF/CONTAK CD Biventricular Pacing Study is a prospective randomized trial to examine the safety and efficacy of biventricular (BV) pacing in patients with standard indications for an ICD, symptomatic heart failure, a LVEF < or = 0.35, and a QRS > or = 120 ms. Patients underwent implantation of a BV pacing and sensing system with backup defibrillation capability, which includes a steroid-eluting coronary venous lead that is advanced into the coronary venous vasculature by over-the-wire techniques. LV pacing threshold, BV impedance, and BV R wave amplitude were measured in 58 consecutive patients. Using a percutaneous over-the-wire insertion technique, steroid-eluting coronary venous leads were associated with satisfactory mean LV pacing threshold, BV impedance, and BV R wave amplitude acutely up to 4 months after implantation. Pacing threshold stabilized 2 weeks after lead implantation and sensing threshold remained stable from the time of implant.
2000
23
1741
1743
ACHTELIK M ;BOCCHIARDO M ;TRAPPE HJ ;GAITA F ;LOZANO I ;NIAZI I ;GOLD M ;YONG P ;DUBY C
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/34249
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact