Patients with primary aldosteronism and with glucocorticoid-suppressible aldosteronism excrete in the urine excessive amounts of the hybrid steroids 18-hydroxycortisol and 18-oxocortisol. The measurement of these steroids aids in the differential diagnosis of various adrenal disorders. We have produced mouse monoclonal antibodies against 18-oxocortisol and polyclonal antibodies against 18-hydroxycortisol and describe a time-resolved fluoroimmunoassay (TR-FIA) technique for the measurement of these steroids in the urine. We have also compared this assay with an ELISA technique for these compounds. We also describe the preparation of in-house Eu(III)-labeled avidin and an enhancement solution and compared to a commercially available Eu(III)-labeled streptavidin and enhancement solutions. The monoclonal antibodies against 18-oxocortisol are sensitive and have a high level of specificity. The TR-FIA technique using in-house prepared reagents or commercial ones were indistinguishable from each other, but at a significant saving. The TR-FIA technique was more sensitive and had a greater precision than the ELISA technique for both steroids.

A time-resolved fluoroimmunoassay for 18-oxocortisol and 18-hydroxycortisol. Development of a monoclonal antibody to 18-oxocortisol.

VEGLIO, Franco;MULATERO, Paolo;
2002-01-01

Abstract

Patients with primary aldosteronism and with glucocorticoid-suppressible aldosteronism excrete in the urine excessive amounts of the hybrid steroids 18-hydroxycortisol and 18-oxocortisol. The measurement of these steroids aids in the differential diagnosis of various adrenal disorders. We have produced mouse monoclonal antibodies against 18-oxocortisol and polyclonal antibodies against 18-hydroxycortisol and describe a time-resolved fluoroimmunoassay (TR-FIA) technique for the measurement of these steroids in the urine. We have also compared this assay with an ELISA technique for these compounds. We also describe the preparation of in-house Eu(III)-labeled avidin and an enhancement solution and compared to a commercially available Eu(III)-labeled streptavidin and enhancement solutions. The monoclonal antibodies against 18-oxocortisol are sensitive and have a high level of specificity. The TR-FIA technique using in-house prepared reagents or commercial ones were indistinguishable from each other, but at a significant saving. The TR-FIA technique was more sensitive and had a greater precision than the ELISA technique for both steroids.
2002
82
83
88
S. MORRA DI CELLA; F. VEGLIO; P.MULATERO; V.CHRISTENSEN; K.AYCOCK; ZHENG ZHU; E.P. GOMEZ-SANCHEZ; C. E.GOMEZ-SANCHEZ.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/37219
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 16