This retrospective study aimed to investigate whether a mandibular implant-retained overdenture designed to counteract the rotation of the denture might influence the clinical outcome, as evaluated through the prosthetic maintenance interventions. The amount of repairs and relines of the mandibular and maxillary dentures required in an experimental group (6 patients wearing an implant-retained overdenture with a metal frame counteracting the rotation) and a control group (6 patients wearing an implant-retained overdenture allowing the rotation) was compared. Both mandibular and maxillary dentures needed few repairs or relines. The 2 types of dentures showed a similar number of maintenance interventions.
Mandibular implant-retained overdentures with 2 different prosthetic designs: a retrospective pilot study on maintenance interventions
CERUTI, Paola;SCHIERANO, Gianmario;MUSSANO, Federico Davide Costanti;
2006-01-01
Abstract
This retrospective study aimed to investigate whether a mandibular implant-retained overdenture designed to counteract the rotation of the denture might influence the clinical outcome, as evaluated through the prosthetic maintenance interventions. The amount of repairs and relines of the mandibular and maxillary dentures required in an experimental group (6 patients wearing an implant-retained overdenture with a metal frame counteracting the rotation) and a control group (6 patients wearing an implant-retained overdenture allowing the rotation) was compared. Both mandibular and maxillary dentures needed few repairs or relines. The 2 types of dentures showed a similar number of maintenance interventions.File | Dimensione | Formato | |
---|---|---|---|
p MIR OVD pros Int J Prost_2006_p557-559.pdf
Accesso riservato
Tipo di file:
POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione
301.44 kB
Formato
Adobe PDF
|
301.44 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.