Priming by X-rays or by beta-rays is generally needed in order to qualify CVD diamond for nuclear detection or for dosimetry. The priming effect is usually attributed in filling the hole traps, which are responsible for the charge collection efficiency of the detector. Emptying the filled traps can be easily detected by thermoluminescence (TL), which is considered to be a measure of the absorbed dose. In this work, we prove that below-gap photocurrent (BGPC) can also be used in the same way and it is dominated by the optical detrapping of holes from the same centers. Time dependence of this beta-rays induced persistent photocurrent (PPC), which in fact, depends only on the total number of photons impinging onto the sample. In fact, at long times or for large number of photons, the photocurrent approaches to the same limit of PC for a null dose. The hole trapping centers

Photocurrent study of beta-ray priming in CVD diamond

MANFREDOTTI, Claudio;VITTONE, Ettore;OLIVERO, Paolo;LO GIUDICE, Alessandro
2004-01-01

Abstract

Priming by X-rays or by beta-rays is generally needed in order to qualify CVD diamond for nuclear detection or for dosimetry. The priming effect is usually attributed in filling the hole traps, which are responsible for the charge collection efficiency of the detector. Emptying the filled traps can be easily detected by thermoluminescence (TL), which is considered to be a measure of the absorbed dose. In this work, we prove that below-gap photocurrent (BGPC) can also be used in the same way and it is dominated by the optical detrapping of holes from the same centers. Time dependence of this beta-rays induced persistent photocurrent (PPC), which in fact, depends only on the total number of photons impinging onto the sample. In fact, at long times or for large number of photons, the photocurrent approaches to the same limit of PC for a null dose. The hole trapping centers
2004
13
914
917
http://www.sciencedirect.com/science/article/pii/S0925963503004667
CVD diamond; Persistent photocurrent (PPC); Below-gap photocurrent (BGPC); Priming; Dosimetry
C. MANFREDOTTI; F. FIZZOTTI; E. VITTONE; C. PAOLINI; P. OLIVERO; A. LO GIUDICE
File in questo prodotto:
File Dimensione Formato  
DRM_13_914.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 573.58 kB
Formato Adobe PDF
573.58 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/37349
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact