The study aimed to investigate the connective tissue seal and the spatial organization of collagen fibers around long-term loaded implants in man. Block specimens containing smooth titanium implant abutments and the surrounding supracrestal connective tissue were obtained from patients rehabilitated for at least 1 year with implant-retained overdentures or implant-supported fixed prostheses and were histologically investigated. The histological features of the connective tissue around long-term loaded titanium abutments were specific: the tissue was rich in collagen fibers, organized in bundles, presenting a constant spatial arrangement, similar to that reported in animal studies. Circular fibers, the most numerous, were located externally, and longitudinal fibers internally. Radial fibers inserted on the abutment surface, similar to those of the periodontal system, were not observed in any case. No histological differences were found between tissue sampled around implants supporting a fixed restoration and those anchoring an overdenture.
Organization of the connective tissue barrier around long-term loaded implant abutments in man.
SCHIERANO, Gianmario;RAMIERI, Guglielmo;AIMETTI, Mario;PRETI, Giulio
2002-01-01
Abstract
The study aimed to investigate the connective tissue seal and the spatial organization of collagen fibers around long-term loaded implants in man. Block specimens containing smooth titanium implant abutments and the surrounding supracrestal connective tissue were obtained from patients rehabilitated for at least 1 year with implant-retained overdentures or implant-supported fixed prostheses and were histologically investigated. The histological features of the connective tissue around long-term loaded titanium abutments were specific: the tissue was rich in collagen fibers, organized in bundles, presenting a constant spatial arrangement, similar to that reported in animal studies. Circular fibers, the most numerous, were located externally, and longitudinal fibers internally. Radial fibers inserted on the abutment surface, similar to those of the periodontal system, were not observed in any case. No histological differences were found between tissue sampled around implants supporting a fixed restoration and those anchoring an overdenture.File | Dimensione | Formato | |
---|---|---|---|
Organiz of the connective... Clinic Oral Implant Res 2002.pdf
Accesso riservato
Tipo di file:
POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione
177.42 kB
Formato
Adobe PDF
|
177.42 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.