Invasiveness of temperature monitoring devices is presently one of the most serious limitations to the application of oncological hyperthermia (HT). A promising approach aims at detecting temperature variations by monitoring the mean grey level (MGL) of the ultrasonographic image of the tissue. Gaseous ultrasound contrast agents (UCA), enhancing Ultrasonic (US) imaging, are expected to be sensitive to temperature, and are therefore a good candidate as temperature monitoring medium. The present study evaluates the 'in vitro' temporal and thermal stability and the correlation between temperature and MGL using a gaseous UCA (SonoVue) as phantom. No statistical differences were detected between the MGL value of the phantom kept at 43.5 degrees C before (215.2+/-3.5) and after 1 h (214.8+/-2.5), showing good stability at HT temperatures. Data of MGL image vs. temperature were obtained during both heating and cooling experiments in the HT range (30-43 degrees C). A good linearity of MGL vs. temperature (R2=0.976) was found with a good accuracy (2.5%) and a sensitivity of about 6.6 MGL/degrees C.

Temperature monitoring using ultrasound contrast agents: in vitro investigation on thermal stability

GUIOT, Caterina;CAVALLI, Roberta;TROTTA, Michele;TODROS, Tullia
2004-01-01

Abstract

Invasiveness of temperature monitoring devices is presently one of the most serious limitations to the application of oncological hyperthermia (HT). A promising approach aims at detecting temperature variations by monitoring the mean grey level (MGL) of the ultrasonographic image of the tissue. Gaseous ultrasound contrast agents (UCA), enhancing Ultrasonic (US) imaging, are expected to be sensitive to temperature, and are therefore a good candidate as temperature monitoring medium. The present study evaluates the 'in vitro' temporal and thermal stability and the correlation between temperature and MGL using a gaseous UCA (SonoVue) as phantom. No statistical differences were detected between the MGL value of the phantom kept at 43.5 degrees C before (215.2+/-3.5) and after 1 h (214.8+/-2.5), showing good stability at HT temperatures. Data of MGL image vs. temperature were obtained during both heating and cooling experiments in the HT range (30-43 degrees C). A good linearity of MGL vs. temperature (R2=0.976) was found with a good accuracy (2.5%) and a sensitivity of about 6.6 MGL/degrees C.
2004
42(1-9)
927
930
GUIOT C.; CAVALLI R.; GAGLIOTI P.; DANELON D.; MUSACCHIO C.; TROTTA M.; TODROS T.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/39898
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact