The packaging and chemical stability of both conventional and highly crosslinked polyethylene (PE) components available for clinical use in Italy were analyzed. A total of 100 sterilized PE components were entered by 18 orthopedic manufacturers into the study. Six of the manufacturers were Italian and the remaining were based in Europe or America. Hydroperoxide, oxidation, and trans-vinylene levels within the PE components were characterized using Fourier-transform infrared spectroscopy (FTIR). None of the 31 gas-sterilized components had detectable free radicals, hydroperoxide content, or oxidation. Among radiation-sterilized inserts, the highest oxidation and hydroperoxide levels were associated with gas-permeable and polymer-barrier packaging. To the authors' knowledge, this is the first study that relates elevated oxidation and hydroperoxide content in gamma-sterilized PE components to certain types of contemporary, polymeric barrier packaging.

Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement components

COSTA, Luigi;BRACCO, Pierangiola;BRACH DEL PREVER, Elena Maria;GALLINARO, Paolo
2006-01-01

Abstract

The packaging and chemical stability of both conventional and highly crosslinked polyethylene (PE) components available for clinical use in Italy were analyzed. A total of 100 sterilized PE components were entered by 18 orthopedic manufacturers into the study. Six of the manufacturers were Italian and the remaining were based in Europe or America. Hydroperoxide, oxidation, and trans-vinylene levels within the PE components were characterized using Fourier-transform infrared spectroscopy (FTIR). None of the 31 gas-sterilized components had detectable free radicals, hydroperoxide content, or oxidation. Among radiation-sterilized inserts, the highest oxidation and hydroperoxide levels were associated with gas-permeable and polymer-barrier packaging. To the authors' knowledge, this is the first study that relates elevated oxidation and hydroperoxide content in gamma-sterilized PE components to certain types of contemporary, polymeric barrier packaging.
2006
78
20
26
UHMWPE; oxidation; barrier packaging
L. COSTA; P. BRACCO; E.M. BRACH DEL PREVER; SM. KURTZ; P. GALLINARO
File in questo prodotto:
File Dimensione Formato  
Brach_oxidation and oxidation_JBMR_2006.pdf

Accesso riservato

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 243.52 kB
Formato Adobe PDF
243.52 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/40163
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 64
  • ???jsp.display-item.citation.isi??? 55
social impact