A new method using high-performance liquid chromatography coupled with photo diode array detection was developed and validated for the quantification of plasma concentrations of the human immunodeficiency syndrome integrase inhibitor raltegravir (RGV), the new nonnucleoside reverse transcriptase inhibitor etravirine (ETV), and 11 other antiretroviral agents: ritonavir, atazanavir, lopinavir, nevirapine, efavirenz, saquinavir, indinavir, nelfinavir, and its metabolite M-8, amprenavir, and darunavir. A simple solid phase extraction procedure was applied to 500 muL aliquots of plasma, and chromatographic separation of the drugs and internal standard (quinoxaline) was achieved with a gradient (acetonitrile and phosphate buffer) on an C-18 reverse-phase analytical column with a 28-minute analytical run time. Calibration curves were optimized according to expected ranges of drug concentrations in patients, and the coefficient of determination (r) was higher than 0.998 for all analytes. Mean intraday and interday precisions (percent relative SD) for all compounds were 3.67% and 6.39%, respectively, and mean accuracy (percent deviation from nominal concentration) was -1.17%. Extraction recovery ranged within 75% and 83% for all drugs analyzed. The solid phase extraction and high-performance liquid chromatography coupled with photo diode array method described allow a specific, sensitive, and reliable simultaneous determination of RGV, ETV, and 11 antiretroviral agents in plasma by a single assay. Good extraction efficiency and low limit of quantification make this a suitable method for use in clinical trials and for therapeutic drug monitoring of RGV, protease inhibitors, and nonnucleoside reverse transcriptase inhibitors, including ETV.

An HPLC-PDA Method for the Simultaneous Quantification of the HIV Integrase Inhibitor Raltegravir, the New Nonnucleoside Reverse Transcriptase Inhibitor Etravirine, and 11 Other Antiretroviral Agents in the Plasma of HIV-Infected Patients

D'AVOLIO, ANTONIO
First
;
BAIETTO, LORENA;SICCARDI, MARCO;SCIANDRA, Mauro;SIMIELE, MARCO;BONORA, Stefano;DI PERRI, Giovanni
Last
2008-01-01

Abstract

A new method using high-performance liquid chromatography coupled with photo diode array detection was developed and validated for the quantification of plasma concentrations of the human immunodeficiency syndrome integrase inhibitor raltegravir (RGV), the new nonnucleoside reverse transcriptase inhibitor etravirine (ETV), and 11 other antiretroviral agents: ritonavir, atazanavir, lopinavir, nevirapine, efavirenz, saquinavir, indinavir, nelfinavir, and its metabolite M-8, amprenavir, and darunavir. A simple solid phase extraction procedure was applied to 500 muL aliquots of plasma, and chromatographic separation of the drugs and internal standard (quinoxaline) was achieved with a gradient (acetonitrile and phosphate buffer) on an C-18 reverse-phase analytical column with a 28-minute analytical run time. Calibration curves were optimized according to expected ranges of drug concentrations in patients, and the coefficient of determination (r) was higher than 0.998 for all analytes. Mean intraday and interday precisions (percent relative SD) for all compounds were 3.67% and 6.39%, respectively, and mean accuracy (percent deviation from nominal concentration) was -1.17%. Extraction recovery ranged within 75% and 83% for all drugs analyzed. The solid phase extraction and high-performance liquid chromatography coupled with photo diode array method described allow a specific, sensitive, and reliable simultaneous determination of RGV, ETV, and 11 antiretroviral agents in plasma by a single assay. Good extraction efficiency and low limit of quantification make this a suitable method for use in clinical trials and for therapeutic drug monitoring of RGV, protease inhibitors, and nonnucleoside reverse transcriptase inhibitors, including ETV.
2008
30
662
669
Antonio Dʼavolio; Lorena Baietto; Marco Siccardi; Mauro Sciandra; Marco Simiele; Valentina Oddone; Stefano Bonora; Giovanni Di Perri
File in questo prodotto:
File Dimensione Formato  
An HPLC-PDA Method for the Simultaneous.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 345.87 kB
Formato Adobe PDF
345.87 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/48533
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 109
  • ???jsp.display-item.citation.isi??? 93
social impact