The design criteria of a scintillator telescope for high energy electrons, consisting of plastic scintillators, a BGO preshower detector, a segmented BGO calorimeter and an aerogel Cherenkov counter are discussed. The performance of the telescope is described using the data collected in an inclusive electron scattering experiment around 1 GeV, with emphasis on the efficiency to electrons, which is enhanced by the analysis of the complete information provided by such a multidetector system.

A Spectrometer For 1 Gev Electrons Using Scintillation Detectors

GERVINO, Gianpiero
1993-01-01

Abstract

The design criteria of a scintillator telescope for high energy electrons, consisting of plastic scintillators, a BGO preshower detector, a segmented BGO calorimeter and an aerogel Cherenkov counter are discussed. The performance of the telescope is described using the data collected in an inclusive electron scattering experiment around 1 GeV, with emphasis on the efficiency to electrons, which is enhanced by the analysis of the complete information provided by such a multidetector system.
1993
324
191
197
M. ANGHINOLFI; P. CORVISIERO; G. COSCIA; L. MAZZASCHI; V. MOKEEV; G. RICCO; M. RIPANI; M. TAIUTI; A. ZUCCHIATTI; N. BIANCHI; E. DESANCTIS; P. L. SANDRI; V. LUCHERINI; V. MUCCIFORA; E. POLLI; A. R. REOLON; P. ROSSI; G. GERVINO
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/50746
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact