Background The potential effects of laparoscopic surgery on intra- and postoperative intraocular pressure (IOP) are not completely understood. Although prior studies have reported that pneumoperitoneum may increase IOP, it is not clear whether this increase is related to the effects of pneumoperitoneum or to the patient’s position, such as the Trendelenburg position. This study aimed to evaluate the potential fluctuations of IOP during colorectal laparoscopic surgery in two groups of patients: those with and those without Trendelenburg positioning. Methods For this prospective study 45- to 85-year-old patients undergoing laparoscopic colorectal surgery were enrolled after a thorough ophthalmologic assessment. The study protocol included measurement of IOP at eight different time points (before, during, and after surgery) using a contact tonometer in both eyes. Results The study enrolled 29 patients: 17 (58.6 %) with Trendelenburg position placement during surgery and 12 (41.4 %) without Trendelenburg positioning. The two groups did not differ in terms of gender, age, body mass index (BMI), American Society of Anesthesiology (ASA) class, or operative time. In all the patients, pneumoperitoneum induction led to a mild rise in IOP, averaging 4.1 mmHg. The patients with Trendelenburg positioning showed a greater increase than the patients without it (5.05 vs 4.23 mmHg at 45 min; p = 0.179), but IOP evaluation 48 h after surgery showed no substantial differences between the two groups. Among the 29 patients, 17 (58.6 %) showed an increase in IOP of 5 mmHg or more during surgery. A greater percentage of the patients who underwent Trendelenburg positioning showed an IOP increase of 5 mmHg or more (76.5 vs 33.3 %; p = 0.020). At the multivariate analysis, no potential predictors of increased IOP during surgery was identified. Conclusions Standard pneumoperitoneum (B14 mmHg) led to mild and reversible IOP increases. A trend was observed toward a greater IOP increase in patients with Trendelenburg positioning. Thus, the patient’s position during surgery may represent a stronger risk factor for IOP increase than pneumoperitoneum-related intraabdominal pressure.
Intraocular pressure variation during colorectal laparoscopic surgery: standard pneumoperitoneum leads to reversible elevation in intraocular pressure
SCOZZARI, Gitana;BERT, Fabrizio;SILIQUINI, Roberta;MORINO, Mario
2013-01-01
Abstract
Background The potential effects of laparoscopic surgery on intra- and postoperative intraocular pressure (IOP) are not completely understood. Although prior studies have reported that pneumoperitoneum may increase IOP, it is not clear whether this increase is related to the effects of pneumoperitoneum or to the patient’s position, such as the Trendelenburg position. This study aimed to evaluate the potential fluctuations of IOP during colorectal laparoscopic surgery in two groups of patients: those with and those without Trendelenburg positioning. Methods For this prospective study 45- to 85-year-old patients undergoing laparoscopic colorectal surgery were enrolled after a thorough ophthalmologic assessment. The study protocol included measurement of IOP at eight different time points (before, during, and after surgery) using a contact tonometer in both eyes. Results The study enrolled 29 patients: 17 (58.6 %) with Trendelenburg position placement during surgery and 12 (41.4 %) without Trendelenburg positioning. The two groups did not differ in terms of gender, age, body mass index (BMI), American Society of Anesthesiology (ASA) class, or operative time. In all the patients, pneumoperitoneum induction led to a mild rise in IOP, averaging 4.1 mmHg. The patients with Trendelenburg positioning showed a greater increase than the patients without it (5.05 vs 4.23 mmHg at 45 min; p = 0.179), but IOP evaluation 48 h after surgery showed no substantial differences between the two groups. Among the 29 patients, 17 (58.6 %) showed an increase in IOP of 5 mmHg or more during surgery. A greater percentage of the patients who underwent Trendelenburg positioning showed an IOP increase of 5 mmHg or more (76.5 vs 33.3 %; p = 0.020). At the multivariate analysis, no potential predictors of increased IOP during surgery was identified. Conclusions Standard pneumoperitoneum (B14 mmHg) led to mild and reversible IOP increases. A trend was observed toward a greater IOP increase in patients with Trendelenburg positioning. Thus, the patient’s position during surgery may represent a stronger risk factor for IOP increase than pneumoperitoneum-related intraabdominal pressure.File | Dimensione | Formato | |
---|---|---|---|
Intraocular pressure variation during colorectal laparosco….pdf
Open Access dal 01/01/2015
Tipo di file:
POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione
451.82 kB
Formato
Adobe PDF
|
451.82 kB | Adobe PDF | Visualizza/Apri |
art%3A10.1007%2Fs00464-013-2919-2.pdf
Accesso riservato
Tipo di file:
PDF EDITORIALE
Dimensione
271.66 kB
Formato
Adobe PDF
|
271.66 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.