The transient and the steady-state single-test tension infiltrometer methods are expected to provide poor hydraulic conductivity K0 estimates in soils situated in the lateral capillarity domain. To evaluate the best strategy for conducting a single-test experiment in these soils, infiltration experiments were numerically simulated for a sandy loam and a clay soil by using two initial pressure heads (−1 and −100 m), four pressure heads at the soil surface (from −0·15 m to −0·01 m), and a maximum duration of 4 h (sandy loam soil) and 12 h (clay soil). The most accurate predictions of K0, differing by a factor of between 0·9 and 1·1 from the true value, were obtained in wet conditions, by applying the transient method to experiments of 1 h in the sandy loam soil and 6 h in the clay soil. Increasing the duration of the experiment beyond this optimal duration determined an overestimation of K0 by a maximum factor of 1·5. A substantially higher overestimation of K0 was detected with the steady-state method. Applying a transient method of analysis to a relatively long-duration experiment conducted in wet soil provided reasonably accurate estimates of K0 in soils situated in the domain of lateral capillarity.

An Evaluation of the Single-test Tension Infiltrometer Method for determining the Hydraulic Conductivity of Lateral Capillarity Domain Soils

FERRARIS, Stefano;
2004-01-01

Abstract

The transient and the steady-state single-test tension infiltrometer methods are expected to provide poor hydraulic conductivity K0 estimates in soils situated in the lateral capillarity domain. To evaluate the best strategy for conducting a single-test experiment in these soils, infiltration experiments were numerically simulated for a sandy loam and a clay soil by using two initial pressure heads (−1 and −100 m), four pressure heads at the soil surface (from −0·15 m to −0·01 m), and a maximum duration of 4 h (sandy loam soil) and 12 h (clay soil). The most accurate predictions of K0, differing by a factor of between 0·9 and 1·1 from the true value, were obtained in wet conditions, by applying the transient method to experiments of 1 h in the sandy loam soil and 6 h in the clay soil. Increasing the duration of the experiment beyond this optimal duration determined an overestimation of K0 by a maximum factor of 1·5. A substantially higher overestimation of K0 was detected with the steady-state method. Applying a transient method of analysis to a relatively long-duration experiment conducted in wet soil provided reasonably accurate estimates of K0 in soils situated in the domain of lateral capillarity.
2004
Inglese
Sì, ma tipo non specificato
87, n.2
247
255
http://www.sciencedirect.com/science/journal/15375110
ITALIA
262
3
BAGARELLO V.; FERRARIS S.; IOVINO M.
info:eu-repo/semantics/article
none
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/5697
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact