Volatile organic compounds indicated in the US-EPA 502.2 method were detected in the drinking water of twenty-one public fountains of the City of Torino The analyses were carried out with P&T/GLC, using as detectors the PID+HECD pair or an ion trap mass spectrometer, The concentration of organohalide species in each sample was below the limit permitted by law and the analytical results made it possible to identify at least two areas of the City with a different quality of water.
Volatile organic compounds in drinking water
ZELANO, Vincenzo;GASTALDI, Daniela;GINEPRO, Marco;OSTACOLI, Giorgio
1998-01-01
Abstract
Volatile organic compounds indicated in the US-EPA 502.2 method were detected in the drinking water of twenty-one public fountains of the City of Torino The analyses were carried out with P&T/GLC, using as detectors the PID+HECD pair or an ion trap mass spectrometer, The concentration of organohalide species in each sample was below the limit permitted by law and the analytical results made it possible to identify at least two areas of the City with a different quality of water.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.