The aim of this review is to present the state of the art of the technology of detection and conditioning systems for surface electromyography (sEMG). The first part of the manuscript focuses on the sEMG electrode system technology: the electrode classification, impedance, noise, transfer function, the spatial filtering effect of surface electrode configurations, the effects of electrode geometry, and location on the recorded sEMG signal. Examples of experimental sEMG signals are provided to show the potential value of high-density sEMG electrode grids and multichannel amplifiers that allow to add spatial information to the temporal information content of the sEMG signal. Furthermore, the results of a simple simulation are reported, in order to emphasize the effects of the subcutaneous tissue layers and of the detection volume on the recorded sEMG signal. The second part of the manuscript focuses on the sEMG amplifier technology: the front end amplifier characteristics for signal conditioning, the methods for stimulation artifact reduction, filtering methods, safety requirements, and the methods for analog-to-digital conversion of the sEMG signal.

Technology and instrumentation for detection and conditioning of the surface electromyographic signal: state of the art.

MINETTO, Marco Alessandro
2009-01-01

Abstract

The aim of this review is to present the state of the art of the technology of detection and conditioning systems for surface electromyography (sEMG). The first part of the manuscript focuses on the sEMG electrode system technology: the electrode classification, impedance, noise, transfer function, the spatial filtering effect of surface electrode configurations, the effects of electrode geometry, and location on the recorded sEMG signal. Examples of experimental sEMG signals are provided to show the potential value of high-density sEMG electrode grids and multichannel amplifiers that allow to add spatial information to the temporal information content of the sEMG signal. Furthermore, the results of a simple simulation are reported, in order to emphasize the effects of the subcutaneous tissue layers and of the detection volume on the recorded sEMG signal. The second part of the manuscript focuses on the sEMG amplifier technology: the front end amplifier characteristics for signal conditioning, the methods for stimulation artifact reduction, filtering methods, safety requirements, and the methods for analog-to-digital conversion of the sEMG signal.
2009
24
2
122
134
Merletti R; Botter A; Troiano A; Merlo E; Minetto MA.
File in questo prodotto:
File Dimensione Formato  
Merletti et al. Clin Biomech 2009.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 714.46 kB
Formato Adobe PDF
714.46 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/60834
Citazioni
  • ???jsp.display-item.citation.pmc??? 42
  • Scopus 260
  • ???jsp.display-item.citation.isi??? 223
social impact