We report a study of B-+/- -> D*K-+/- decays with D* decaying to D pi(0) or D gamma, using 383 x 10(6) B (B) over bar pairs collected at the Y(4S) resonance with the BABAR detector at the SLAC PEP-II B Factory. The D meson decays under study include a non-CP mode (K-+/- pi(-/+)), CP-even modes ((KK -/+)-K-+/-, pi(+/-)pi(-/+)), and CP-odd modes (K-s(0)pi(0), K-s(0)phi, K-s(0)omega).We measure ratios (R*(CP +/-)) of branching fractions of decays to CP eigenmode states and to flavor-specific states as well as CP asymmetries (A*(CP +/-)) These measurements are sensitive to the unitarity triangle angle gamma. We obtain A*(CP+) = -0.11 +/- 0.09 +/- 0.01, R*(CP) = 1.31 +/- 0.13 +/- 0.04, and A*(CP-) = 0.06 +/- 0.10 +/- 0.02, R-CP-(*) = 1.10 +/- 0.12 +/- 0.04, where the first error is statistical and the second error is systematic. Translating our results into an alternative parametrization, widely used for related measurements, we obtain x(+)* = 0. 11 +/- 0.06 +/- 0.02 and x(-)* = 0.00 +/- 0.06 +/- 0.02. No significant CP-violating charge asymmetry is found in either the flavor-specific mode D -> K-+/- pi(-/+) or in B-+/- -> D*pi(+/-) decays.

Measurement of ratios of branching fractions and CP-violating asymmetries of B-+/- -> D*K-+/- decays

BIANCHI, Fabrizio;GAMBA, Diego;PELLICCIONI, Mario;
2008-01-01

Abstract

We report a study of B-+/- -> D*K-+/- decays with D* decaying to D pi(0) or D gamma, using 383 x 10(6) B (B) over bar pairs collected at the Y(4S) resonance with the BABAR detector at the SLAC PEP-II B Factory. The D meson decays under study include a non-CP mode (K-+/- pi(-/+)), CP-even modes ((KK -/+)-K-+/-, pi(+/-)pi(-/+)), and CP-odd modes (K-s(0)pi(0), K-s(0)phi, K-s(0)omega).We measure ratios (R*(CP +/-)) of branching fractions of decays to CP eigenmode states and to flavor-specific states as well as CP asymmetries (A*(CP +/-)) These measurements are sensitive to the unitarity triangle angle gamma. We obtain A*(CP+) = -0.11 +/- 0.09 +/- 0.01, R*(CP) = 1.31 +/- 0.13 +/- 0.04, and A*(CP-) = 0.06 +/- 0.10 +/- 0.02, R-CP-(*) = 1.10 +/- 0.12 +/- 0.04, where the first error is statistical and the second error is systematic. Translating our results into an alternative parametrization, widely used for related measurements, we obtain x(+)* = 0. 11 +/- 0.06 +/- 0.02 and x(-)* = 0.00 +/- 0.06 +/- 0.02. No significant CP-violating charge asymmetry is found in either the flavor-specific mode D -> K-+/- pi(-/+) or in B-+/- -> D*pi(+/-) decays.
2008
78
092002
-
B. Aubert;M. Bona;Y. Karyotakis;J. P. Lees;V. Poireau;E. Prencipe;X. Prudent;V. Tisserand;J. G. Tico;E. Grauges;L. Lopez;A. Palano;M. Pap...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/71908
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 88
social impact