Dislocation is a common and important complication of total hip arthroplasty (THA). Larger femoral heads may reduce the risk of dislocation and improve the range of movement. The aim of this study was to compare the relative risk (RR) of dislocation during the first year after THA between implants with 28 mm and 36 mm femoral heads. 198 consecutive hips with 28 mm femoral head (Group-28) and 259 hips with 36 mm femoral head (Group-36) were studied. The patients were assessed preoperatively and periodically using the Harris hip score (HHS) and radiographic analysis. The relative risk (RR) of dislocation was calculated. The average HHS significantly improved from a preoperative baseline to the last follow-up at 82.1 months (28 mm) and 44.3 months (36 mm). No statistically significant differences were revealed between the two groups for HHS results and complications (p>0.05), but the difference in RR of dislocation within the first year between the two groups was 7.85 (95% CI: 1.34-46.03), p=0.046.Although dislocation is multifactorial in etiology, the two groups were homogenous for all principal contributing factors except the diameter of the femoral head. Therefore, the use of 36-mm heads can reduce the risk of dislocation following THA by a factor of 8 compared to conventional 28 mm heads.

Dislocation rate after hip arthroplasty within the first postoperative year: 36 mm versus 28 mm femoral heads

CROVA, Maurizio;MASSAZZA, Giuseppe
2011-01-01

Abstract

Dislocation is a common and important complication of total hip arthroplasty (THA). Larger femoral heads may reduce the risk of dislocation and improve the range of movement. The aim of this study was to compare the relative risk (RR) of dislocation during the first year after THA between implants with 28 mm and 36 mm femoral heads. 198 consecutive hips with 28 mm femoral head (Group-28) and 259 hips with 36 mm femoral head (Group-36) were studied. The patients were assessed preoperatively and periodically using the Harris hip score (HHS) and radiographic analysis. The relative risk (RR) of dislocation was calculated. The average HHS significantly improved from a preoperative baseline to the last follow-up at 82.1 months (28 mm) and 44.3 months (36 mm). No statistically significant differences were revealed between the two groups for HHS results and complications (p>0.05), but the difference in RR of dislocation within the first year between the two groups was 7.85 (95% CI: 1.34-46.03), p=0.046.Although dislocation is multifactorial in etiology, the two groups were homogenous for all principal contributing factors except the diameter of the femoral head. Therefore, the use of 36-mm heads can reduce the risk of dislocation following THA by a factor of 8 compared to conventional 28 mm heads.
2011
21
5
559
564
Dislocation rate, Large femoral heads, Total hip arthroplasty
Bistolfi A; Crova M; Rosso F; Titolo P; Ventura S; Massazza G
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/89202
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 33
social impact