The current study evaluated the success and the possible complication of intermaxillary fixation with self-tapping and self-drilling screws (STSDSs) in nondislocated or slightly dislocated mandibular fractures.Forty patients with mandibular fractures, treated with intermaxillary fixation using STSDSs, were clinically assessed by means of a dental vitality test and evaluation of tooth mobility adjacent to the cortical screw holes, and radiologically by means of a panoramic dental radiograph upon removal of the screws.The main complication was screw loss in 4.4% of cases, followed by coverage by oral mucosa in 1.2% of cases. However, no dental root damage, screw breakage, malocclusion, or poor consolidation of mandibular fractures was observed.The use of STSDSs for intermaxillary fixation is a useful alternative to the use of arch bars in the treatment of some types of mandibular fractures. In addition, there is no risk of dental lesions as with self-tapping screws.

Self-tapping and self-drilling screws for intermaxillary fixation in management of mandibular fractures

GALLESIO, Cesare;
2009-01-01

Abstract

The current study evaluated the success and the possible complication of intermaxillary fixation with self-tapping and self-drilling screws (STSDSs) in nondislocated or slightly dislocated mandibular fractures.Forty patients with mandibular fractures, treated with intermaxillary fixation using STSDSs, were clinically assessed by means of a dental vitality test and evaluation of tooth mobility adjacent to the cortical screw holes, and radiologically by means of a panoramic dental radiograph upon removal of the screws.The main complication was screw loss in 4.4% of cases, followed by coverage by oral mucosa in 1.2% of cases. However, no dental root damage, screw breakage, malocclusion, or poor consolidation of mandibular fractures was observed.The use of STSDSs for intermaxillary fixation is a useful alternative to the use of arch bars in the treatment of some types of mandibular fractures. In addition, there is no risk of dental lesions as with self-tapping screws.
2009
20
1
68
70
Roccia F; Rossi P; Gallesio C; Boffano P
File in questo prodotto:
File Dimensione Formato  
gallesio 442042.pdf

Accesso riservato

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 430.57 kB
Formato Adobe PDF
430.57 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/98963
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 16
social impact