Accurate measurement of the tissue pH in vivo by MRI may be of clinical value for both diagnosis and selection/monitoring of therapy. To act as pH reporters, MRI contrast agents have to provide responsiveness to pH that does not require prior knowledge of the actual concentration of the contrast agent. This work deals with the use of a paramagnetic gadolinium(III) complex, loaded into liposomes, whose relaxometric properties are affected by the pH of the medium. In this system, the amphiphilic metal complex, which contains a moiety whose protonation changes the coordination properties of the metal chelate, experiences a different intraliposomial distribution depending on the pH conditions. The pH of the solution can be unambiguously identified by exploiting the peculiar characteristics of the resulting NMRD profiles, and a ratiometric pH-responsive method has been set up by comparing the relaxation enhancement at different magnetic field strengths.

Relaxometric Investigations and MRI Evaluation of a Liposome-Loaded pH-Responsive Gadolinium(III) Complex

GIANOLIO, Eliana;NAPOLITANO, ROBERTA;BARONI, SIMONA;AIME, Silvio
2012-01-01

Abstract

Accurate measurement of the tissue pH in vivo by MRI may be of clinical value for both diagnosis and selection/monitoring of therapy. To act as pH reporters, MRI contrast agents have to provide responsiveness to pH that does not require prior knowledge of the actual concentration of the contrast agent. This work deals with the use of a paramagnetic gadolinium(III) complex, loaded into liposomes, whose relaxometric properties are affected by the pH of the medium. In this system, the amphiphilic metal complex, which contains a moiety whose protonation changes the coordination properties of the metal chelate, experiences a different intraliposomial distribution depending on the pH conditions. The pH of the solution can be unambiguously identified by exploiting the peculiar characteristics of the resulting NMRD profiles, and a ratiometric pH-responsive method has been set up by comparing the relaxation enhancement at different magnetic field strengths.
2012
Inglese
Sì, ma tipo non specificato
51
7210
7217
8
ITALIA
262
6
Gianolio E; Porto S; Napolitano R; Baroni S; Giovenzana GB; Aime S
info:eu-repo/semantics/article
none
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/132209
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 33
social impact