Aims The previous literature has suggested that the iatrogenic atrial septal defects (IASDs) may follow left atrial (LA) access by transseptal (TS) puncture, especially in the case of a single TS for more than one catheter. The aim of the present study is to describe the prevalence of patent foramen ovale (PFO) and IASDs in a cohort of atrial fibrillation (AF) patients undergoing redo catheter ablation (CA) procedures in a high-volume centre accessing LA by a standardized single TS puncture. Methods and results Patients (n = 197) who underwent at least one redo AFCA, between 2004 and 2012, were retrospectively enroled. Transoesophageal echocardiography was performed before each procedure during which LA was accessed via a PFO, if present, or by single TS for both the mapping and ablation catheters. At baseline, PFO was detected in 43 (21.8%) patients. Clinical and echocardiographic parameters recorded did not differ within patients presenting with or without PFO. Left atrium was accessed via PFO in 39 (90.7% of those with PFO) patients during the first procedure. New-onset IASD occurred in 11 (5.6%) patients following the first procedure and in 1 (2.2%) patient following the second procedure. The clinical and echocardiographic parameters did not differ within the patients irrespective of whether IASD was reported or not. No TS-related complications occurred. Conclusion In the present cohort, LA access by PFO or single TS for both the mapping and ablation catheters lead to a small risk of asymptomatic IASD, not increased by redo procedures, confirming that it represents a safe approach. No clinical and/or echocardiographic parameters seemed to predict IASD occurrence.
Iatrogenic atrial septal defects following atrial fibrillation transcatheter ablation: a relevant entity?
ANSELMINO, Matteo;BATTAGLIA, Alberto;GAITA, Fiorenzo
2014-01-01
Abstract
Aims The previous literature has suggested that the iatrogenic atrial septal defects (IASDs) may follow left atrial (LA) access by transseptal (TS) puncture, especially in the case of a single TS for more than one catheter. The aim of the present study is to describe the prevalence of patent foramen ovale (PFO) and IASDs in a cohort of atrial fibrillation (AF) patients undergoing redo catheter ablation (CA) procedures in a high-volume centre accessing LA by a standardized single TS puncture. Methods and results Patients (n = 197) who underwent at least one redo AFCA, between 2004 and 2012, were retrospectively enroled. Transoesophageal echocardiography was performed before each procedure during which LA was accessed via a PFO, if present, or by single TS for both the mapping and ablation catheters. At baseline, PFO was detected in 43 (21.8%) patients. Clinical and echocardiographic parameters recorded did not differ within patients presenting with or without PFO. Left atrium was accessed via PFO in 39 (90.7% of those with PFO) patients during the first procedure. New-onset IASD occurred in 11 (5.6%) patients following the first procedure and in 1 (2.2%) patient following the second procedure. The clinical and echocardiographic parameters did not differ within the patients irrespective of whether IASD was reported or not. No TS-related complications occurred. Conclusion In the present cohort, LA access by PFO or single TS for both the mapping and ablation catheters lead to a small risk of asymptomatic IASD, not increased by redo procedures, confirming that it represents a safe approach. No clinical and/or echocardiographic parameters seemed to predict IASD occurrence.File | Dimensione | Formato | |
---|---|---|---|
1283027_2013-12-24 ReReResubmission.pdf
Open Access dal 19/02/2015
Tipo di file:
POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione
15.68 MB
Formato
Adobe PDF
|
15.68 MB | Adobe PDF | Visualizza/Apri |
1283027_Europace-2014-Anselmino-europace_euu020.pdf
Accesso riservato
Tipo di file:
PDF EDITORIALE
Dimensione
331.17 kB
Formato
Adobe PDF
|
331.17 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.