A simple approach such as the anodic activation of a glassy carbon electrode (GCE) can be used successfully to improve the detection of acetaminophen at very low concentration levels. In this work, we observed that the exposure of a GCE to a high potential (2 V vs Ag/AgCl) for a limited time period (60 s) in the presence of 50 mM borate/phosphate buffer (pH 9) provides a strongly electro-activated surface. The activated surface was characterized by means of several techniques (electrochemistry, EIS, SEM, AFM, m-Raman, XPS). It appeared that the anodization procedure gave rise to a strong oxygen-based functionalization that did not affect morphologically the electrode surface. The mechanism of interaction of the activated electrode with the analyte was studied by electrochemical methods, then the electrode was applied to the electroanalysis of acetaminophen by differential pulse voltammetry. In this application, the method showed promising analytical performance, detecting nanomolar traces of acetaminophen.

Electrocatalysis in the oxidation of acetaminophen with an electrochemically activated glassy carbon electrode

CHIAVAZZA, ENRICO;BERTO, Silvia;GIACOMINO, AGNESE;MALANDRINO, Mery;BAROLO, CLAUDIA;PRENESTI, Enrico;VIONE, Davide Vittorio;ABOLLINO, Ornella
Last
2016-01-01

Abstract

A simple approach such as the anodic activation of a glassy carbon electrode (GCE) can be used successfully to improve the detection of acetaminophen at very low concentration levels. In this work, we observed that the exposure of a GCE to a high potential (2 V vs Ag/AgCl) for a limited time period (60 s) in the presence of 50 mM borate/phosphate buffer (pH 9) provides a strongly electro-activated surface. The activated surface was characterized by means of several techniques (electrochemistry, EIS, SEM, AFM, m-Raman, XPS). It appeared that the anodization procedure gave rise to a strong oxygen-based functionalization that did not affect morphologically the electrode surface. The mechanism of interaction of the activated electrode with the analyte was studied by electrochemical methods, then the electrode was applied to the electroanalysis of acetaminophen by differential pulse voltammetry. In this application, the method showed promising analytical performance, detecting nanomolar traces of acetaminophen.
2016
192
139
147
http://dx.doi.org/10.1016/j.electacta.2016.01.187
Acetominophen oxidation, Glassy carbon electrode, Anodization, Electrochemical activation
Chiavazza, Enrico; Berto, Silvia; Giacomino, Agnese; Malandrino, Mery; Barolo, Claudia; Prenesti, Enrico; Vione, Davide; Abollino, Ornella
File in questo prodotto:
File Dimensione Formato  
activated GCE_AperTO.pdf

Open Access dal 30/01/2018

Descrizione: Articolo principale
Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 1.74 MB
Formato Adobe PDF
1.74 MB Adobe PDF Visualizza/Apri
2016_activated GCE for acetamonophen.pdf

Accesso riservato

Descrizione: Articolo principale
Tipo di file: PDF EDITORIALE
Dimensione 2.8 MB
Formato Adobe PDF
2.8 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
2016_El Acta and suppl_activated GCE for acetamonophen-unito.pdf

Accesso riservato

Descrizione: Pdf Editoriale con Supplementary data
Tipo di file: PDF EDITORIALE
Dimensione 3.72 MB
Formato Adobe PDF
3.72 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1558784
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 24
social impact