We designed a versatile inorganic probe based on functionalized TiO2 nanoparticles for labeling immunoreagents and developing immunological tests. Similarly to enzymatic probes traditionally used in immunoassay, the TiO2 probe could be covalently linked to antigens or antibodies and exploited as the signal reporter in immunoassays. The TiO2 probe allowed revealing the rate of antigen-antibody complex formation by promoting the oxidation of a suitable chromogenic substrate with absorption in the visible. We demonstrated the suitability of the TiO2 probe as a label for immunoassay by coupling it to human serum albumin and developing a direct competitive assay to measure micro- and macro-albuminuria for diabetes diagnosis. The developed TiO2-based assay showed high sensitivity (detection limit 1.4 mg/l), wide dynamic range (6-1270 mg/l) and acceptable precision (within- and between-assay coefficient of variation %<20%) and accuracy (75-95 %) for measuring albumin in human urine. The method is fully compatible with materials and equipment of standard enzyme immunoassay (except for the need of UV irradiation), while the inorganic probe is more robust towards chemical and physical conditions and shows better long term stability compared to enzymes

Functionalized TiO2 nanoparticles as labels for immunoassay

SARRO, MARCO;ANFOSSI, Laura;BAGGIANI, Claudio;GIOVANNOLI, Cristina;CALZA, Paola
2016-01-01

Abstract

We designed a versatile inorganic probe based on functionalized TiO2 nanoparticles for labeling immunoreagents and developing immunological tests. Similarly to enzymatic probes traditionally used in immunoassay, the TiO2 probe could be covalently linked to antigens or antibodies and exploited as the signal reporter in immunoassays. The TiO2 probe allowed revealing the rate of antigen-antibody complex formation by promoting the oxidation of a suitable chromogenic substrate with absorption in the visible. We demonstrated the suitability of the TiO2 probe as a label for immunoassay by coupling it to human serum albumin and developing a direct competitive assay to measure micro- and macro-albuminuria for diabetes diagnosis. The developed TiO2-based assay showed high sensitivity (detection limit 1.4 mg/l), wide dynamic range (6-1270 mg/l) and acceptable precision (within- and between-assay coefficient of variation %<20%) and accuracy (75-95 %) for measuring albumin in human urine. The method is fully compatible with materials and equipment of standard enzyme immunoassay (except for the need of UV irradiation), while the inorganic probe is more robust towards chemical and physical conditions and shows better long term stability compared to enzymes
2016
1
2021
2027
M.Sarro; L.Anfossi; C.Baggiani; C.Giovannoli; M.Cerruti; P.Calza
File in questo prodotto:
File Dimensione Formato  
chsel16_1_2021.pdf

Accesso riservato

Descrizione: articolo come pubblicato
Tipo di file: PDF EDITORIALE
Dimensione 771.07 kB
Formato Adobe PDF
771.07 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
chsel16_1_2021_draft.pdf

Open Access dal 02/09/2018

Descrizione: postprint per open access
Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 907.09 kB
Formato Adobe PDF
907.09 kB Adobe PDF Visualizza/Apri
chsel16_1_2021_si.pdf

Accesso aperto

Descrizione: supporting informations
Tipo di file: MATERIALE NON BIBLIOGRAFICO
Dimensione 430.95 kB
Formato Adobe PDF
430.95 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1593479
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact