The aim of the study was to evaluate the influence of a single partial-body cryotherapy (PBC) session on the maximum handgrip strength (JAMAR Hydraulic Hand dynamometer). Two hundred healthy adults were randomized into a PBC group and a control group (50 males and 50 females in each group). After the initial handgrip strength test (T0), the experimental group performed a 150 seconds session of PBC (temperature range between -130 and -160 °C), whilst the control group stayed in a thermo neutral room (22.0 ± 0.5 °C). Immediately after, both groups performed another handgrip strength test (T1). Data underlined that both groups showed an increase in handgrip strength values, especially the experimental group (Control: T0=39.48 kg, T1=40.01 kg; PBC: T0=39.61 kg, T1=41.34 kg). The analysis reported also a significant effect related to gender (F=491.99, P<0.05), with females showing lower handgrip strength values compared with males (females=30.43 kg, males=52.27 kg). Findings provide the first evidence that a single session of PBC leads to the improvement of muscle strength in healthy people. The results of the study implies that PBC could be performed also before a training session or a sport competition, to increase hand isometric strength.

Acute effects of partial-body cryotherapy on isometric strength: maximum handgrip strength evaluation

PIZZIGALLI, Luisa;CAFFARO, FEDERICA;MICHELETTI CREMASCO, MARGHERITA
Last
2017-01-01

Abstract

The aim of the study was to evaluate the influence of a single partial-body cryotherapy (PBC) session on the maximum handgrip strength (JAMAR Hydraulic Hand dynamometer). Two hundred healthy adults were randomized into a PBC group and a control group (50 males and 50 females in each group). After the initial handgrip strength test (T0), the experimental group performed a 150 seconds session of PBC (temperature range between -130 and -160 °C), whilst the control group stayed in a thermo neutral room (22.0 ± 0.5 °C). Immediately after, both groups performed another handgrip strength test (T1). Data underlined that both groups showed an increase in handgrip strength values, especially the experimental group (Control: T0=39.48 kg, T1=40.01 kg; PBC: T0=39.61 kg, T1=41.34 kg). The analysis reported also a significant effect related to gender (F=491.99, P<0.05), with females showing lower handgrip strength values compared with males (females=30.43 kg, males=52.27 kg). Findings provide the first evidence that a single session of PBC leads to the improvement of muscle strength in healthy people. The results of the study implies that PBC could be performed also before a training session or a sport competition, to increase hand isometric strength.
2017
31
12
3497
3502
cryocabin, hand dynamometer, muscle performance, cryostimulation, hand grip strenght
De Nardi, M.; Pizzigalli, Luisa; Benis, R.; Caffaro, Federica; MICHELETTI CREMASCO, Margherita
File in questo prodotto:
File Dimensione Formato  
CRIO Accettato in stampa JSCR-08-7978_R1.pdf

Accesso aperto

Descrizione: articolo completo con note
Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 1.76 MB
Formato Adobe PDF
1.76 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1621256
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact