A Fast gas chromatography-mass spectrometry method for plant sterols/stanols analysis was developed, using a short capillary gas chromatography column (10 m x 0.1 mm internal diameter x 0.1 μm film thickness) coated with 5% diphenyl-polysiloxane. A silylated mixture of the main plant sterols/stanols standards (beta-sitosterol, campesterol, stigmasterol, campestanol, sitostanol) was well separated in 1.5 min, with a good peak resolution (>1.4, determined on a critical chromatographic peak pair (beta-sitosterol and sitostanol)), repeatability (<13%) and sensitivity (<0.017 ng mL-1). The suitability of this Fast chromatography method was tested on plant sterols/stanols-enriched dairy products (yogurt and milk), which were subjected to lipid extraction, cold saponification and silylation prior to injection. The analytical performance (sensitivity <0.256 ng mL-1 and repeatability <10.36%) and significant reduction of the analysis time and consumables, demonstrates that Fast gas chromatography-mass spectrometry could be also employed for the plant sterols/stanols analysis in functional dairy products.

Analysis of phytosterols and phytostanols in enriched dairy products by Fast gas chromatography-mass spectrometry

V. Cardenia;
2014-01-01

Abstract

A Fast gas chromatography-mass spectrometry method for plant sterols/stanols analysis was developed, using a short capillary gas chromatography column (10 m x 0.1 mm internal diameter x 0.1 μm film thickness) coated with 5% diphenyl-polysiloxane. A silylated mixture of the main plant sterols/stanols standards (beta-sitosterol, campesterol, stigmasterol, campestanol, sitostanol) was well separated in 1.5 min, with a good peak resolution (>1.4, determined on a critical chromatographic peak pair (beta-sitosterol and sitostanol)), repeatability (<13%) and sensitivity (<0.017 ng mL-1). The suitability of this Fast chromatography method was tested on plant sterols/stanols-enriched dairy products (yogurt and milk), which were subjected to lipid extraction, cold saponification and silylation prior to injection. The analytical performance (sensitivity <0.256 ng mL-1 and repeatability <10.36%) and significant reduction of the analysis time and consumables, demonstrates that Fast gas chromatography-mass spectrometry could be also employed for the plant sterols/stanols analysis in functional dairy products.
2014
37
2911
2919
Fast GC-MS; Phytosterols; Phytostanols; Enriched products; Functional dairy products
R. Inchingolo; V. Cardenia; M. T. Rodriguez-Estrada
File in questo prodotto:
File Dimensione Formato  
J Sep Sci 2014.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 509.31 kB
Formato Adobe PDF
509.31 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Deroga.pdf

Accesso riservato

Descrizione: deroga
Tipo di file: DEROGA (OBBLIGATORIO ALLEGARE FILE CON MOTIVAZIONE)
Dimensione 20.8 kB
Formato Adobe PDF
20.8 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1689136
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 24
social impact