Background Finding of intracardiac lead masses in patients with cardiac implantable electronic devices remains controversial, as such masses have been observed in cases of exclusively local infections whereas they have not been recognized in patients with positive cultures of intravascular lead fragments. In this study, we aim to describe the prevalence of intracardiac lead masses in true asymptomatic patients with cardiac implantable electronic devices, to identify their predictive factors and to define their prognostic impact at long-term follow-up. Methods Seventy-eight consecutive patients admitted over a 6-month period for elective generator replacement without clinical evidence of infection were evaluated by transthoracic and transesophageal echocardiography and prospectively followed at in-clinic follow-up visits. Results Lead masses were found in 10 patients (12.8%). These patients had more frequently right ventricular dysfunction at univariate analysis (OR 2.71, PU0.010) and after baseline variables adjustment (hazard ratio 6.25, PU0.012). At 5-year follow-up without any specific therapy, none of the patients suffered from any cardiac device infections, or developed clinical signs of infections. Conclusion There is an evidence of clinical lead masses in asymptomatic patients with cardiac implantable electronic devices. The value of these findings is still debated for aetiological interpretation and for therapeutic strategy, but they are not necessarily associated with an infection.

Prevalence and prognosis of lead masses in patients with cardiac implantable electronic devices without infection

Errigo, Daniele;Peyracchia, Mattia;Frea, Simone;Castagno, Davide;Budano, Carlo;Giustetto, Carla;Rinaldi, Mauro
Last
2019-01-01

Abstract

Background Finding of intracardiac lead masses in patients with cardiac implantable electronic devices remains controversial, as such masses have been observed in cases of exclusively local infections whereas they have not been recognized in patients with positive cultures of intravascular lead fragments. In this study, we aim to describe the prevalence of intracardiac lead masses in true asymptomatic patients with cardiac implantable electronic devices, to identify their predictive factors and to define their prognostic impact at long-term follow-up. Methods Seventy-eight consecutive patients admitted over a 6-month period for elective generator replacement without clinical evidence of infection were evaluated by transthoracic and transesophageal echocardiography and prospectively followed at in-clinic follow-up visits. Results Lead masses were found in 10 patients (12.8%). These patients had more frequently right ventricular dysfunction at univariate analysis (OR 2.71, PU0.010) and after baseline variables adjustment (hazard ratio 6.25, PU0.012). At 5-year follow-up without any specific therapy, none of the patients suffered from any cardiac device infections, or developed clinical signs of infections. Conclusion There is an evidence of clinical lead masses in asymptomatic patients with cardiac implantable electronic devices. The value of these findings is still debated for aetiological interpretation and for therapeutic strategy, but they are not necessarily associated with an infection.
2019
20
6
372
378
defibrillator, infection, lead extraction, lead masses, lead vegetations, pacemaker, transoesophageal echocardiography
Golzio, Pier Giorgio; Errigo, Daniele; Peyracchia, Mattia; Gallo, Elisa; Frea, Simone; Castagno, Davide; Budano, Carlo; Giustetto, Carla; Rinaldi, Mau...espandi
File in questo prodotto:
File Dimensione Formato  
Golzio et al-2019 JCM-Prevalence and prognosis of lead masses.docx

Accesso riservato

Descrizione: Articolo completo
Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 1.04 MB
Formato Microsoft Word XML
1.04 MB Microsoft Word XML   Visualizza/Apri   Richiedi una copia
Golzio et al-2019 JCM-Prevalence and prognosis of lead masses.pdf

Open Access dal 02/06/2020

Descrizione: Articolo completo
Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 615.4 kB
Formato Adobe PDF
615.4 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1701637
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19