Hemp (Cannabis sativa L.) has become widely used in several sectors due to the presence of various bioactive compounds such as terpenes and cannabidiol. In general, terpenes and cannabidiol content is determined separately, which is time consuming. Thus, a fast gas chromatography with flame ionization detection method was validated for simultaneous determination of both terpenes and cannabidiol in hemp. The method enabled a rapid detection of 29 different terpenes and cannabidiol within a total analysis time of 16 min, with satisfactory sensitivity (limit of detection = 0.03–0.27 µg/mL, limit of quantitation = 0.10–0.89 µg/mL). The inter- and intraday precision (RSD) was <7.82 and <3.59%, respectively. Recoveries at two spiked concentration levels (low, 3.15 µg/mL; high, 20.0 µg/mL) were determined on both apical leaves (78.55–101.52%) and inflorescences (77.52–107.10%). The reproducibility (RSD) was <5.94 and <5.51% in apical leaves and inflorescences, respectively. The proposed and validated method is highly sensitive, robust, fast, and accurate for determination of the main terpenes and cannabidiol in hemp and could be routinely used for quality control.

Simultaneous determination of terpenes and cannabidiol in hemp (Cannabis sativa L.) by fast gas chromatography with flame ionization detection

Sgorbini B.;Cardenia V.
Last
2020-01-01

Abstract

Hemp (Cannabis sativa L.) has become widely used in several sectors due to the presence of various bioactive compounds such as terpenes and cannabidiol. In general, terpenes and cannabidiol content is determined separately, which is time consuming. Thus, a fast gas chromatography with flame ionization detection method was validated for simultaneous determination of both terpenes and cannabidiol in hemp. The method enabled a rapid detection of 29 different terpenes and cannabidiol within a total analysis time of 16 min, with satisfactory sensitivity (limit of detection = 0.03–0.27 µg/mL, limit of quantitation = 0.10–0.89 µg/mL). The inter- and intraday precision (RSD) was <7.82 and <3.59%, respectively. Recoveries at two spiked concentration levels (low, 3.15 µg/mL; high, 20.0 µg/mL) were determined on both apical leaves (78.55–101.52%) and inflorescences (77.52–107.10%). The reproducibility (RSD) was <5.94 and <5.51% in apical leaves and inflorescences, respectively. The proposed and validated method is highly sensitive, robust, fast, and accurate for determination of the main terpenes and cannabidiol in hemp and could be routinely used for quality control.
2020
43
14
2817
2826
cannabidiol; cannabis; fast gas chromatography; hemp; terpenes
Bakro F.; Jedryczka M.; Wielgusz K.; Sgorbini B.; Inchingolo R.; Cardenia V.
File in questo prodotto:
File Dimensione Formato  
jssc.201900822.pdf

Accesso riservato

Descrizione: Articolo principale
Tipo di file: PDF EDITORIALE
Dimensione 2.24 MB
Formato Adobe PDF
2.24 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Deroga.pdf

Accesso riservato

Descrizione: deroga
Tipo di file: DEROGA (OBBLIGATORIO ALLEGARE FILE CON MOTIVAZIONE)
Dimensione 20.8 kB
Formato Adobe PDF
20.8 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1759661
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 17
social impact