Rapid and sensitive screening of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential to limit the spread of the global pandemic we are facing. Quantitative real-time reverse transcription-polymerase chain reaction (qRT-PCR) is currently used for the clinical diagnosis of SARS-CoV-2 infection using nasopharyngeal swabs, tracheal aspirates, or bronchoalveolar lavage (BAL) samples. Despite the high sensitivity of the qRT-PCR method, false negative outcomes might occur, especially in patients with a low viral load. Here, we developed a multiplex qRT-PCR methodology for the simultaneous detection of SARS-CoV-2 genome (N gene) and of the human RNAse P gene as internal control. We found that multiplex qRT-PCR was effective in detecting SARS-Cov-2 infection in human specimens with 100% sensitivity. Notably, patients with few copies of SARS-CoV-2 RNA (<5 copies/reaction) were successfully detected by the novel multiplex qRT-PCR method. Finally, we assessed the efficacy of multiplex qRT-PCR on human nasopharyngeal swabs without RNA extraction. Collectively, our results provide evidence of a novel and reliable tool for SARS-CoV-2 RNA detection in human specimens, which allows the testing capacity to be expanded and the RNA extraction step to be bypassed.

A novel multiplex qrt-pcr assay to detect sars-cov-2 infection: High sensitivity and increased testing capacity

Petrillo S.
;
Carrà Giovanna
;
Bottino P.;Zanotto E.;De Santis M. C.;Margaria J. P.;Giorgio A.;Mandili G.;Martini M.;Cavallo R.;Altruda F.
2020-01-01

Abstract

Rapid and sensitive screening of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential to limit the spread of the global pandemic we are facing. Quantitative real-time reverse transcription-polymerase chain reaction (qRT-PCR) is currently used for the clinical diagnosis of SARS-CoV-2 infection using nasopharyngeal swabs, tracheal aspirates, or bronchoalveolar lavage (BAL) samples. Despite the high sensitivity of the qRT-PCR method, false negative outcomes might occur, especially in patients with a low viral load. Here, we developed a multiplex qRT-PCR methodology for the simultaneous detection of SARS-CoV-2 genome (N gene) and of the human RNAse P gene as internal control. We found that multiplex qRT-PCR was effective in detecting SARS-Cov-2 infection in human specimens with 100% sensitivity. Notably, patients with few copies of SARS-CoV-2 RNA (<5 copies/reaction) were successfully detected by the novel multiplex qRT-PCR method. Finally, we assessed the efficacy of multiplex qRT-PCR on human nasopharyngeal swabs without RNA extraction. Collectively, our results provide evidence of a novel and reliable tool for SARS-CoV-2 RNA detection in human specimens, which allows the testing capacity to be expanded and the RNA extraction step to be bypassed.
2020
Inglese
Esperti anonimi
8
7
1
10
10
COVID-19; Direct multiplex qRT-PCR; Multiplex qRT-PCR; QRT-PCR; SARS-CoV-2
no
1 – prodotto con file in versione Open Access (allegherò il file al passo 6 - Carica)
262
12
Petrillo S.; Carrà Giovanna; Bottino P.; Zanotto E.; De Santis M.C.; Margaria J.P.; Giorgio A.; Mandili G.; Martini M.; Cavallo R.; Barberio Davide; A...espandi
info:eu-repo/semantics/article
open
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
File Dimensione Formato  
A Novel Multiplex qRT-PCR Assay to Detect SARS-CoV-2 Infection High Sensitivity and Increased Testing Capacity.pdf

Accesso aperto

Tipo di file: PDF EDITORIALE
Dimensione 1.58 MB
Formato Adobe PDF
1.58 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1761875
Citazioni
  • ???jsp.display-item.citation.pmc??? 29
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 36
social impact